Worked example

M2 drawdown to a drop structure

A mild prismatic canal is controlled just upstream of a drop. Compare depths of 0.85 m at the control and 0.94 m upstream.

Results ↓

Inputs

Channel section
m³/s
m
Enter 0 for a triangular section. Set side slope to 0 for a rectangle.
Use a positive slope for falling bed, zero for level or a negative value for adverse slope.
Profile controls
m
m
m
m
Use 1 for uniform section velocity.

Hydraulic readout

M2 · Upstream profile

Reach distance: 62.0004 m, Normal depth: 1.02445 m, Critical depth: 0.654781 m, Min. freeboard: 0.8888 m

Gradually varied water-surface profileThe direct-step stations are plotted with the channel bed, critical depth and normal depth where defined. The second chart compares depth and available freeboard.REACH DISTANCE62 mNORMAL DEPTH1.0245 mCRITICAL DEPTH0.65478 mMIN. FREEBOARD0.8888 mWater surface · downstream →WaterNormal yₙCrit. y꜀Channel depth & freeboardDepthLimitBankAvailable freeboard0.8888 m / 0.1524 m
  • Twenty equal depth steps. Station x increases downstream. Check sensitivity to step size near normal depth and evaluate transitions separately.

Calculation details

Profile type
M2
Bed slope class
Mild
Direction
Upstream
Target station
-62.0004 m
Required freeboard
0.1524 m

Direct-step station schedule

StationmDepthmVelocitym/sFroudeFriction slope
00.851.70930.65340.0031175
-1.74360.85451.69830.647740.0030597
-3.57970.8591.68750.642150.0030031
-5.51370.86351.67680.636640.0029479
-7.55140.8681.66610.63120.002894
-9.6990.87251.65560.625830.0028413
-11.9630.8771.64530.620540.0027898
-14.3520.88151.6350.615310.0027395
-16.8730.8861.62480.610150.0026903
-19.5350.89051.61480.605060.0026422
-22.3490.8951.60480.600030.0025952
-25.3250.89951.5950.595070.0025492
-28.4750.9041.58520.590170.0025043
-31.8130.90851.57560.585330.0024604
-35.3550.9131.5660.580560.0024174
-39.1160.91751.55660.575840.0023754
-43.1170.9221.54720.571180.0023342
-47.3790.92651.5380.566580.002294
-51.9270.9311.52880.562040.0022547
-56.790.93551.51970.557560.0022162
-620.941.51070.553130.0021785

Interpreting this example

Both depths lie between the normal and critical references. The M2 drawdown deepens when traveling upstream.

Δx = (E₂ − E₁)/(S₀ − S̄f) · E = y + α V²/(2g)

Each step averages the friction slope at its endpoints. Normal depth is an asymptote and may not lie in the requested interval. Critical depth can be a boundary at a control. The energy coefficient also enters the energy-minimum depth.

Steady, one-dimensional flow in a prismatic channel is assumed. Use a finer or adaptive calculation near normal depth and a separate model for rapid changes.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet