Worked example
M2 drawdown to a drop structure
A mild prismatic canal is controlled just upstream of a drop. Compare depths of 0.85 m at the control and 0.94 m upstream.
Inputs
Hydraulic readout
M2 · Upstream profile
Reach distance: 62.0004 m, Normal depth: 1.02445 m, Critical depth: 0.654781 m, Min. freeboard: 0.8888 m
Input values
- Discharge Q
- 11.3267 m³/s
- Bottom width b
- 6.096 m
- Side slope z (H:1V)
- 2
- Bed slope S₀
- 0.0016
- Manning n
- 0.025
- Control depth y₁
- 0.85 m
- Target depth y₂
- 0.94 m
- Bank depth
- 1.8288 m
- Minimum freeboard
- 0.1524 m
- Velocity-head factor α
- 1
- Twenty equal depth steps. Station x increases downstream. Check sensitivity to step size near normal depth and evaluate transitions separately.
Calculation details
- Profile type
- M2
- Bed slope class
- Mild
- Direction
- Upstream
- Target station
- -62.0004 m
- Required freeboard
- 0.1524 m
Direct-step station schedule
| Stationm | Depthm | Velocitym/s | Froude | Friction slope |
|---|---|---|---|---|
| 0 | 0.85 | 1.7093 | 0.6534 | 0.0031175 |
| -1.7436 | 0.8545 | 1.6983 | 0.64774 | 0.0030597 |
| -3.5797 | 0.859 | 1.6875 | 0.64215 | 0.0030031 |
| -5.5137 | 0.8635 | 1.6768 | 0.63664 | 0.0029479 |
| -7.5514 | 0.868 | 1.6661 | 0.6312 | 0.002894 |
| -9.699 | 0.8725 | 1.6556 | 0.62583 | 0.0028413 |
| -11.963 | 0.877 | 1.6453 | 0.62054 | 0.0027898 |
| -14.352 | 0.8815 | 1.635 | 0.61531 | 0.0027395 |
| -16.873 | 0.886 | 1.6248 | 0.61015 | 0.0026903 |
| -19.535 | 0.8905 | 1.6148 | 0.60506 | 0.0026422 |
| -22.349 | 0.895 | 1.6048 | 0.60003 | 0.0025952 |
| -25.325 | 0.8995 | 1.595 | 0.59507 | 0.0025492 |
| -28.475 | 0.904 | 1.5852 | 0.59017 | 0.0025043 |
| -31.813 | 0.9085 | 1.5756 | 0.58533 | 0.0024604 |
| -35.355 | 0.913 | 1.566 | 0.58056 | 0.0024174 |
| -39.116 | 0.9175 | 1.5566 | 0.57584 | 0.0023754 |
| -43.117 | 0.922 | 1.5472 | 0.57118 | 0.0023342 |
| -47.379 | 0.9265 | 1.538 | 0.56658 | 0.002294 |
| -51.927 | 0.931 | 1.5288 | 0.56204 | 0.0022547 |
| -56.79 | 0.9355 | 1.5197 | 0.55756 | 0.0022162 |
| -62 | 0.94 | 1.5107 | 0.55313 | 0.0021785 |
Interpreting this example
Both depths lie between the normal and critical references. The M2 drawdown deepens when traveling upstream.
Δx = (E₂ − E₁)/(S₀ − S̄f) · E = y + α V²/(2g)
Each step averages the friction slope at its endpoints. Normal depth is an asymptote and may not lie in the requested interval. Critical depth can be a boundary at a control. The energy coefficient also enters the energy-minimum depth.
Steady, one-dimensional flow in a prismatic channel is assumed. Use a finer or adaptive calculation near normal depth and a separate model for rapid changes.
Worked examples
Open a case to load its inputs and interpretation.
- Chow M1 backwater behind a damAn idealized dam backs Chow’s 400 cfs trapezoidal channel up to 5 ft. Trace the profile toward 3.4 ft using α = 1.10.
- M3 rise after a gateSupercritical flow enters a mild reach at 0.39 m. Calculate where it could reach 0.49 m if the modeled regime persists.
- S2 profile at a steep chuteA trapezoidal chute with a 2.3% bed grade and 0.025 roughness approaches its steep normal depth from above.
- H2 profile in a level canalA level rectangular canal is 3 m wide and carries 4.5 m³/s. Its 1.4 m control depth is traced toward 1.1 m.
- A3 reach on an adverse invertA 1.2 m flume carries 1.4 m³/s while the invert rises 0.15% downstream. Trace shallow flow from 0.28 to 0.38 m.
- Backwater at a low canal bankA downstream check raises the water to 1.69 m beside a bank 1.84 m above the invert. The required clearance is 0.25 m.