Worked example

1.5 Pool Turnovers for 15,000 Gallons at 50 GPM

One turnover is 15,000 gallons. At 1.5 turnovers the comparison pumps 22,500 gallons daily. Flow in gallons per minute becomes an hourly volume after multiplying by 60.

Jump to results

Example readings

Pool and baseline pump
US gal
US gpm
rpm
W
Variable-speed comparison
rpm
days
USD/kWh

Results

Estimate

Monthly electricity saved
145.1 kWh
Monthly cost difference
26.13 USD
Variable-speed runtime
10.78 hr/day
Estimated variable-speed draw
421 W
Estimated variable-speed flow
34.8 US gpm
Baseline runtime
7.5 hr/day
Baseline monthly cost
50.63 USD
Variable-speed monthly cost
24.5 USD
Monthly cost by pump speed
MONTHLY COST$0 RPM3,864 RPMBaseline $50.632,400 RPM: $24.5
Daily turnover runtime comparison
Turnovers per dayBaselineVariable speed
1×5 hr7.19 hr
1.5×7.5 hr10.78 hr
2×10 hr14.38 hr

Export & share

Worked calculation

  1. 15,000 US gal ÷ 50 US gpm ÷ 60 × 1.5 = 7.5 hr/day at baseline speed.
  2. 2,400 ÷ 3,450 = 0.6957 speed ratio. Multiply flow by the ratio and power by the ratio cubed to get 420.8 W.
  3. For 30 days and equivalent circulation, electricity is 281.25 kWh baseline vs. 136.11 kWh variable speed. At $0.18/kWh the difference is $26.13.
  • The affinity-law estimate pairs equal daily circulation volumes and assumes the same hydraulic system. Confirm actual flow and watts at each speed, plus the equipment’s minimum flow.
  • A turnover means a water volume equal to the pool passed through the pump. Actual mixing, sanitation, skimming and equipment run times determine the operating schedule.

Common questions

How many gallons per hour is 50 US gallons per minute?

At a steady 50 gpm, multiply by 60 minutes for 3,000 US gallons per hour.

Does 1.5 turnovers mean every gallon went through the filter?

Some water recirculates while other pockets mix more slowly. The total is a nominal circulated volume.

Method and safety references