Monthly Pool Pump Costs at 2,200 RPM and $0.31 per kWh
The candidate speed comparison uses a higher energy rate and a 31-day period. Keep the same circulation goal and change the rate to match the variable energy charge on your bill.
18,000 US gal ÷ 58 US gpm ÷ 60 × 1 = 5.17 hr/day at baseline speed.
2,200 ÷ 3,450 = 0.6377 speed ratio. Multiply flow by the ratio and power by the ratio cubed to get 376 W.
For 31 days and equivalent circulation, electricity is 232.5 kWh baseline vs. 94.54 kWh variable speed. At $0.31/kWh the difference is $42.77.
The affinity-law estimate pairs equal daily circulation volumes and assumes the same hydraulic system. Confirm actual flow and watts at each speed, plus the equipment’s minimum flow.
A turnover means a water volume equal to the pool passed through the pump. Actual mixing, sanitation, skimming and equipment run times determine the operating schedule.
Common questions
Should my pump cost include the utility’s fixed monthly fee?
Use the marginal charge per kWh to compare energy schedules. A fixed fee generally stays the same under either pump setting.
What if daytime and overnight electricity have different rates?
Estimate each block at its applicable price and add the costs. A single blended rate approximates the bill only if it reflects the actual usage mix.
18,000 US gal ÷ 58 US gpm ÷ 60 × 1 = 5.17 hr/day at baseline speed.
2,200 ÷ 3,450 = 0.6377 speed ratio. Multiply flow by the ratio and power by the ratio cubed to get 376 W.
For 31 days and equivalent circulation, electricity is 232.5 kWh baseline vs. 94.54 kWh variable speed. At $0.31/kWh the difference is $42.77.
Verify pump flow, pressure and operating limits from the equipment documentation. Use a water test kit to check sanitizer and pH independently of estimated turnover. Read the product label, wear the required protection and keep swimmers out during treatment. Never mix pool chemicals or chlorine types, and never add acid and chlorine together. Verify readings with a pool or spa test kit before adding chemicals and retest after circulation and before use.