Measure & circulate
Pool Pump Turnover and Variable-Speed Energy Calculator
Enter a measured flow and wattage at a known speed. Compare them with a candidate RPM at the same daily water volume. Check equipment flow requirements before using the suggested runtime.
Your readings
Results
Estimate- Monthly electricity saved
- 200 kWh
- Monthly cost difference
- 36 USD
- Variable-speed runtime
- 11.11 hr/day
- Estimated variable-speed draw
- 200 W
- Estimated variable-speed flow
- 30 US gpm
- Baseline runtime
- 5.56 hr/day
- Baseline monthly cost
- 48 USD
- Variable-speed monthly cost
- 12 USD
| Turnovers per day | Baseline | Variable speed |
|---|---|---|
| 1× | 5.56 hr | 11.11 hr |
| 1.5× | 8.33 hr | 16.67 hr |
| 2× | 11.11 hr | 22.22 hr |
Export & share
How the calculation works
- 20,000 US gal ÷ 60 US gpm ÷ 60 × 1 = 5.56 hr/day at baseline speed.
- 1,725 ÷ 3,450 = 0.5 speed ratio. Multiply flow by the ratio and power by the ratio cubed to get 200 W.
- For 30 days and equivalent circulation, electricity is 266.67 kWh baseline vs. 66.67 kWh variable speed. At $0.18/kWh the difference is $36.
- The affinity-law estimate pairs equal daily circulation volumes and assumes the same hydraulic system. Confirm actual flow and watts at each speed, plus the equipment’s minimum flow.
- A turnover means a water volume equal to the pool passed through the pump. Actual mixing, sanitation, skimming and equipment run times determine the operating schedule.
Common questions
Why does the savings calculation allow the slower speed to run longer?
The comparison holds daily circulated volume constant. At half estimated flow it takes twice as long to move that volume, while affinity-law power falls to about one eighth.
How can I verify an actual daily circulation estimate?
Read a compatible flow meter with the system in normal operation. Keep filter pressure, valve positions and any heater or salt-cell minimum flow in mind.