Measure & circulate

Pool Pump Turnover and Variable-Speed Energy Calculator

Enter a measured flow and wattage at a known speed. Compare them with a candidate RPM at the same daily water volume. Check equipment flow requirements before using the suggested runtime.

Jump to results

Your readings

Pool and baseline pump
US gal
US gpm
rpm
W
Variable-speed comparison
rpm
days
USD/kWh

Results

Estimate

Monthly electricity saved
200 kWh
Monthly cost difference
36 USD
Variable-speed runtime
11.11 hr/day
Estimated variable-speed draw
200 W
Estimated variable-speed flow
30 US gpm
Baseline runtime
5.56 hr/day
Baseline monthly cost
48 USD
Variable-speed monthly cost
12 USD
Monthly cost by pump speed
MONTHLY COST$0 RPM3,864 RPMBaseline $481,725 RPM: $12
Daily turnover runtime comparison
Turnovers per dayBaselineVariable speed
1×5.56 hr11.11 hr
1.5×8.33 hr16.67 hr
2×11.11 hr22.22 hr

Export & share

How the calculation works

  1. 20,000 US gal ÷ 60 US gpm ÷ 60 × 1 = 5.56 hr/day at baseline speed.
  2. 1,725 ÷ 3,450 = 0.5 speed ratio. Multiply flow by the ratio and power by the ratio cubed to get 200 W.
  3. For 30 days and equivalent circulation, electricity is 266.67 kWh baseline vs. 66.67 kWh variable speed. At $0.18/kWh the difference is $36.
  • The affinity-law estimate pairs equal daily circulation volumes and assumes the same hydraulic system. Confirm actual flow and watts at each speed, plus the equipment’s minimum flow.
  • A turnover means a water volume equal to the pool passed through the pump. Actual mixing, sanitation, skimming and equipment run times determine the operating schedule.

Common questions

Why does the savings calculation allow the slower speed to run longer?

The comparison holds daily circulated volume constant. At half estimated flow it takes twice as long to move that volume, while affinity-law power falls to about one eighth.

How can I verify an actual daily circulation estimate?

Read a compatible flow meter with the system in normal operation. Keep filter pressure, valve positions and any heater or salt-cell minimum flow in mind.

Method and safety references