At half speed the estimated flow halves and the estimated watts fall to one eighth. A fair comparison doubles the slower runtime to move the same pool volume.
20,000 US gal ÷ 60 US gpm ÷ 60 × 1 = 5.56 hr/day at baseline speed.
1,725 ÷ 3,450 = 0.5 speed ratio. Multiply flow by the ratio and power by the ratio cubed to get 200 W.
For 30 days and equivalent circulation, electricity is 266.67 kWh baseline vs. 66.67 kWh variable speed. At $0.18/kWh the difference is $36.
The affinity-law estimate pairs equal daily circulation volumes and assumes the same hydraulic system. Confirm actual flow and watts at each speed, plus the equipment’s minimum flow.
A turnover means a water volume equal to the pool passed through the pump. Actual mixing, sanitation, skimming and equipment run times determine the operating schedule.
Common questions
Why is monthly kWh roughly one quarter at half RPM here?
One eighth of the power times twice the runtime equals one quarter of the energy. The calculation assumes unchanged hydraulics and the same circulated volume.
How much does the 3,450 RPM baseline draw per day?
At one turnover, multiply its displayed daily runtime by 1.6 kW. That gives about 8.89 kWh per day for the example.
20,000 US gal ÷ 60 US gpm ÷ 60 × 1 = 5.56 hr/day at baseline speed.
1,725 ÷ 3,450 = 0.5 speed ratio. Multiply flow by the ratio and power by the ratio cubed to get 200 W.
For 30 days and equivalent circulation, electricity is 266.67 kWh baseline vs. 66.67 kWh variable speed. At $0.18/kWh the difference is $36.
Verify pump flow, pressure and operating limits from the equipment documentation. Use a water test kit to check sanitizer and pH independently of estimated turnover. Read the product label, wear the required protection and keep swimmers out during treatment. Never mix pool chemicals or chlorine types, and never add acid and chlorine together. Verify readings with a pool or spa test kit before adding chemicals and retest after circulation and before use.