Worked example
When 1,200 RPM Cannot Fit Two Turnovers Into One Day
The reduced flow makes the modeled hours exceed one day. The cost chart can still compare the math, while the warning identifies the infeasible schedule.
Example readings
Results
Estimate- Monthly electricity saved
- 896.6 kWh
- Monthly cost difference
- 161.39 USD
- Variable-speed runtime
- 57.5 hr/day
- Estimated variable-speed draw
- 72 W
- Estimated variable-speed flow
- 17.4 US gpm
- Baseline runtime
- 20 hr/day
- Baseline monthly cost
- 183.6 USD
- Variable-speed monthly cost
- 22.21 USD
| Turnovers per day | Baseline | Variable speed |
|---|---|---|
| 1× | 10 hr | 28.75 hr |
| 1.5× | 15 hr | 43.13 hr |
| 2× | 20 hr | 57.5 hr |
Export & share
Worked calculation
- 30,000 US gal ÷ 50 US gpm ÷ 60 × 2 = 20 hr/day at baseline speed.
- 1,200 ÷ 3,450 = 0.3478 speed ratio. Multiply flow by the ratio and power by the ratio cubed to get 71.5 W.
- For 30 days and equivalent circulation, electricity is 1,020 kWh baseline vs. 123.4 kWh variable speed. At $0.18/kWh the difference is $161.39.
- The affinity-law estimate pairs equal daily circulation volumes and assumes the same hydraulic system. Confirm actual flow and watts at each speed, plus the equipment’s minimum flow.
- A turnover means a water volume equal to the pool passed through the pump. Actual mixing, sanitation, skimming and equipment run times determine the operating schedule.
- At least one runtime exceeds 24 hours per day. Its energy and cost are theoretical because the requested turnover does not fit in one day.
Common questions
What should I change when the candidate runtime is greater than 24 hours?
Check the measured flow and equipment schedule. A higher candidate speed or a different equipment-approved circulation goal may fit.
Can a very low RPM fail even if the turnover fits?
Yes. Heaters, salt cells and filtration can have minimum flow requirements. Verify those and the pump manual before scheduling.