3C95 ferrite with 1 A ripple

Estimate a low-ripple choke using 3C95 material and 28 turns.

Design inputs

Winding & geometry
Excitation & material
View live readout ↑

Live readout

Edit inputs
Peak flux
87.91 mT
Flux headroom
78.56 %
Air gap
2.382 mm
Core loss
6.85e-4 W
Core magnetization Core magnetization B–H reference BField H → Core gapPeak B87.9 mTSaturation410 mTAir gap2.38 mm
The B–H curve and gap are illustrative. The marker and labels follow the calculated flux and the selected material threshold.
Flux headroom available

Saturation uses the selected threshold. Check flux and inductance at operating temperature.

Peak flux / saturation87.91 mT / 410 mT

AC flux amplitude / saturation7.326 mT / 410 mT

Result breakdown
Peak flux density87.9121 mT
Minimum flux density73.2601 mT
AC flux swing (peak-to-peak)14.652 mT
AC flux amplitude7.32601 mT
Midpoint DC current5.5 A
DC magnetizing field2,655.17 A/m
Material saturation threshold410 mT
Peak-flux headroom322.088 mT
Peak-flux headroom78.558 %
Relative permeability used3,000
Equivalent discrete air gap2.3821 mm
Estimated ungapped inductance3,974.79 µH
Steinmetz coefficient k1.76
Steinmetz frequency exponent α1.37
Steinmetz flux exponent β2.34
Modeled magnetic loss density152.215 W/m³
Modeled core loss6.84969e-4 W

Worked calculation

Bmax = 32 µH × 6 A / (28 × 78 mm²) = 87.9121 mT

Increase ripple with peak current held fixed to see the independent effect on the core-loss estimate.

Flux

Bmax = L·Ipk/(N·Ae) | ΔB = L·ΔIpp/(N·Ae)

Compare the absolute endpoint flux with the saturation threshold. A bipolar peak-to-peak swing can exceed that threshold while both endpoints stay within it. Hdc = N·Idc/ℓe uses the midpoint of the entered triangular current. Use it with the actual powder-core DC-bias curve and enter inductance at the operating bias.

Gap

ℓg = μ₀·N²·Ae/L − ℓe/μr

If the computed gap is negative, the ungapped core cannot reach the target L at this turn count. The estimate neglects fringing and uses linear permeability. For a powder core the result is an equivalent reluctance, not a machining dimension.

Core loss

Pcore = Ve · k · fs^α · (ΔB/2)^β

Enter frequency in Hz and flux in tesla when fitting custom coefficients for a loss density in W/m³. Ferrite coefficients are approximate fits to typical hot datasheet points. Powder presets use published coefficients for representative 60-permeability toroids. Use your exact material, geometry, temperature and waveform for final loss estimates.