N87 ferrite choke for a 9 A buck

Screen a compact N87 choke for a high-current buck stage with 2.2 A peak-to-peak ripple.

Design inputs

Winding & geometry
Excitation & material
View live readout ↑

Live readout

Edit inputs
Peak flux
158.2 mT
Flux headroom
59.44 %
Air gap
1.122 mm
Core loss
0.02051 W
Core magnetization Core magnetization B–H reference BField H → Core gapPeak B158 mTSaturation390 mTAir gap1.12 mm
The B–H curve and gap are illustrative. The marker and labels follow the calculated flux and the selected material threshold.
Flux headroom available

Saturation uses the selected threshold. Check flux and inductance at operating temperature.

Peak flux / saturation158.2 mT / 390 mT

AC flux amplitude / saturation19.34 mT / 390 mT

Result breakdown
Peak flux density158.203 mT
Minimum flux density119.531 mT
AC flux swing (peak-to-peak)38.6719 mT
AC flux amplitude19.3359 mT
Midpoint DC current7.9 A
DC magnetizing field2,633.33 A/m
Material saturation threshold390 mT
Peak-flux headroom231.797 mT
Peak-flux headroom59.4351 %
Relative permeability used2,200
Equivalent discrete air gap1.122 mm
Estimated ungapped inductance943.651 µH
Steinmetz coefficient k1.7592
Steinmetz frequency exponent α1.35893
Steinmetz flux exponent β2.09727
Modeled magnetic loss density6,680.59 W/m³
Modeled core loss0.0205094 W

Worked calculation

Bmax = 18 µH × 9 A / (16 × 64 mm²) = 158.203 mT

Read peak flux for saturation and half the AC swing for core loss. They answer different design questions.

Flux

Bmax = L·Ipk/(N·Ae) | ΔB = L·ΔIpp/(N·Ae)

Compare the absolute endpoint flux with the saturation threshold. A bipolar peak-to-peak swing can exceed that threshold while both endpoints stay within it. Hdc = N·Idc/ℓe uses the midpoint of the entered triangular current. Use it with the actual powder-core DC-bias curve and enter inductance at the operating bias.

Gap

ℓg = μ₀·N²·Ae/L − ℓe/μr

If the computed gap is negative, the ungapped core cannot reach the target L at this turn count. The estimate neglects fringing and uses linear permeability. For a powder core the result is an equivalent reluctance, not a machining dimension.

Core loss

Pcore = Ve · k · fs^α · (ΔB/2)^β

Enter frequency in Hz and flux in tesla when fitting custom coefficients for a loss density in W/m³. Ferrite coefficients are approximate fits to typical hot datasheet points. Powder presets use published coefficients for representative 60-permeability toroids. Use your exact material, geometry, temperature and waveform for final loss estimates.