PowerConvLab · Design worksheet
Custom material with fitted loss coefficients
Flux headroom available · Saturation uses the selected threshold. Check flux and inductance at operating temperature.
Inputs
- Winding turns
- 22 turns
- Target inductance
- 27 µH
- Effective core area
- 72 mm²
- Magnetic path length
- 60 mm
- Effective core volume
- 4.32 cm³
- Peak current magnitude
- 9 A
- AC peak-to-peak current
- 3.8 A
- Switching frequency
- 170 kHz
- Core material
- Custom material
- Saturation threshold
- 360 mT
- Relative permeability μᵣ
- 1,650
- Steinmetz coefficient k
- 2.1
- Frequency exponent α
- 1.4
- Flux exponent β
- 2.28
Calculated results
- Peak flux density
- 153.409 mT
- Minimum flux density
- 88.6364 mT
- AC flux swing (peak-to-peak)
- 64.7727 mT
- AC flux amplitude
- 32.3864 mT
- Midpoint DC current
- 7.1 A
- DC magnetizing field
- 2,603.33 A/m
- Material saturation threshold
- 360 mT
- Peak-flux headroom
- 206.591 mT
- Peak-flux headroom
- 57.3864 %
- Relative permeability used
- 1,650
- Equivalent discrete air gap
- 1.58554 mm
- Estimated ungapped inductance
- 1,204.26 µH
- Steinmetz coefficient k
- 2.1
- Steinmetz frequency exponent α
- 1.4
- Steinmetz flux exponent β
- 2.28
- Modeled magnetic loss density
- 17,720.4 W/m³
- Modeled core loss
- 0.0765521 W