PowerConvLab · Design worksheet
3C95 ferrite with 1 A ripple
Flux headroom available · Saturation uses the selected threshold. Check flux and inductance at operating temperature.
Inputs
- Winding turns
- 28 turns
- Target inductance
- 32 µH
- Effective core area
- 78 mm²
- Magnetic path length
- 58 mm
- Effective core volume
- 4.5 cm³
- Peak current magnitude
- 6 A
- AC peak-to-peak current
- 1 A
- Switching frequency
- 115 kHz
- Core material
- 3C95 ferrite · 410 mT
Calculated results
- Peak flux density
- 87.9121 mT
- Minimum flux density
- 73.2601 mT
- AC flux swing (peak-to-peak)
- 14.652 mT
- AC flux amplitude
- 7.32601 mT
- Midpoint DC current
- 5.5 A
- DC magnetizing field
- 2,655.17 A/m
- Material saturation threshold
- 410 mT
- Peak-flux headroom
- 322.088 mT
- Peak-flux headroom
- 78.558 %
- Relative permeability used
- 3,000
- Equivalent discrete air gap
- 2.3821 mm
- Estimated ungapped inductance
- 3,974.79 µH
- Steinmetz coefficient k
- 1.76
- Steinmetz frequency exponent α
- 1.37
- Steinmetz flux exponent β
- 2.34
- Modeled magnetic loss density
- 152.215 W/m³
- Modeled core loss
- 6.84969e-4 W