PowerConvLab · Design worksheet
High Flux choke for a 22 A peak
Flux headroom available · The gap is an equivalent reluctance. Use the powder core DC-bias curve for actual inductance.
Inputs
- Winding turns
- 30 turns
- Target inductance
- 25 µH
- Effective core area
- 90 mm²
- Magnetic path length
- 70 mm
- Effective core volume
- 6.3 cm³
- Peak current magnitude
- 22 A
- AC peak-to-peak current
- 5 A
- Switching frequency
- 90 kHz
- Core material
- High Flux · 1,500 mT
Calculated results
- Peak flux density
- 203.704 mT
- Minimum flux density
- 157.407 mT
- AC flux swing (peak-to-peak)
- 46.2963 mT
- AC flux amplitude
- 23.1481 mT
- Midpoint DC current
- 19.5 A
- DC magnetizing field
- 8,357.14 A/m
- Material saturation threshold
- 1,500 mT
- Peak-flux headroom
- 1,296.3 mT
- Peak-flux headroom
- 86.4198 %
- Relative permeability used
- 60
- Equivalent discrete air gap
- 2.90484 mm
- Estimated ungapped inductance
- 87.2465 µH
- Steinmetz coefficient k
- 28.7665
- Steinmetz frequency exponent α
- 1.311
- Steinmetz flux exponent β
- 2.218
- Modeled magnetic loss density
- 21,203 W/m³
- Modeled core loss
- 0.133579 W