ASME B31.3 flexibility screen
Carbon steel U-loop on a hot process run
A carbon steel pipe rack needs space for a symmetric loop between two anchors after startup.
Inputs
Results
Edit inputs- Movement ΔL
- 3.84in
- Minimum leg
- 16.16ft
- Leg stress
- 16.12ksi
- Stress margin
- 3.88ksi
The provided leg meets the entered stress range in the guided-cantilever screen.
Thermal movement and routing
All calculated values
| Temperature change ΔT | 320 °F |
|---|---|
| Signed run movement ΔL | 3.84 in |
| Motion assigned to each leg | 1.92 in |
| Minimum flexing leg | 16.158 ft |
| Width at minimum U-loop height | 11.31 ft |
| Width at provided U-loop height | 12.6 ft |
| Screened displacement stress | 16.12 ksi |
| Available stress range | 3.88 ksi |
| Allowable range used | 80.6 % |
| Nominal elastic modulus | 29.01 Mpsi |
| Linear expansion coefficient | 0.000012 1/°C |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Calculate signed pipe movement3.84 in
- Find the flexing leg length16.158 ft
- Compare with available stress range3.88 ksi
The screen splits movement across two legs. Check both leg length and proposed loop width against the rack envelope.
Model and limits
Use the length between effective anchors and the install-to-operating temperature difference. The guided-cantilever screen assigns the full displacement to a single L-leg or shares it equally across the two idealized legs of a Z-offset or U-loop.
Use a project-approved allowable displacement stress range Sₐ. Representative moduli and coefficients are constant over the entered temperature range. Confirm temperature-dependent properties, anchor loads, direction of movement, elbow flexibility, fatigue cycles and stress intensification using the governing B31.3 edition and a pipe stress analysis. U-loop width is a layout estimate from the entered aspect ratio.
View equations and references