ASME B31.3 flexibility screen
Cold service contraction at an L-bend
A stainless transfer line cools after installation, drawing the movable end back toward the anchor.
Inputs
Results
Edit inputs- Movement ΔL
- -34.1mm
- Minimum leg
- 3.18m
- Leg stress
- 762MPa
- Stress margin
- -644MPa
Increase the free flexing length or revise the routing before detailed flexibility analysis.
Thermal movement and routing
All calculated values
| Temperature change ΔT | -59 °C |
|---|---|
| Signed run movement ΔL | -34.102 mm |
| Motion assigned to each leg | 34.102 mm |
| Minimum flexing leg | 3.176 m |
| Screened displacement stress | 762 MPa |
| Available stress range | -644 MPa |
| Allowable range used | 645.8 % |
| Nominal elastic modulus | 193 GPa |
| Linear expansion coefficient | 0.000017 1/°C |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Calculate signed pipe movement-34.102 mm
- Find the flexing leg length3.176 m
- Compare with available stress range-644 MPa
Movement is signed while the screening stress uses the magnitude. Check the required clearance in the contraction direction.
Model and limits
Use the length between effective anchors and the install-to-operating temperature difference. The guided-cantilever screen assigns the full displacement to a single L-leg or shares it equally across the two idealized legs of a Z-offset or U-loop.
Use a project-approved allowable displacement stress range Sₐ. Representative moduli and coefficients are constant over the entered temperature range. Confirm temperature-dependent properties, anchor loads, direction of movement, elbow flexibility, fatigue cycles and stress intensification using the governing B31.3 edition and a pipe stress analysis. U-loop width is a layout estimate from the entered aspect ratio.
View equations and references