ASME B31.3 flexibility screen
U-loop with constrained leg height
A hot header crosses a crowded pipe rack that limits the available loop height to five feet.
Inputs
Results
Edit inputs- Movement ΔL
- 7.04in
- Minimum leg
- 23.06ft
- Leg stress
- 382.9ksi
- Stress margin
- -364.9ksi
Increase the free flexing length or revise the routing before detailed flexibility analysis.
Thermal movement and routing
All calculated values
| Temperature change ΔT | 400 °F |
|---|---|
| Signed run movement ΔL | 7.04 in |
| Motion assigned to each leg | 3.52 in |
| Minimum flexing leg | 23.061 ft |
| Width at minimum U-loop height | 25.367 ft |
| Width at provided U-loop height | 5.5 ft |
| Screened displacement stress | 382.9 ksi |
| Available stress range | -364.9 ksi |
| Allowable range used | 2,127.2 % |
| Nominal elastic modulus | 29.01 Mpsi |
| Linear expansion coefficient | 0.000012 1/°C |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Calculate signed pipe movement7.04 in
- Find the flexing leg length23.061 ft
- Compare with available stress range-364.9 ksi
The provided leg exceeds the screened displacement stress range. An alternate framing layout or full flexibility model is needed.
Model and limits
Use the length between effective anchors and the install-to-operating temperature difference. The guided-cantilever screen assigns the full displacement to a single L-leg or shares it equally across the two idealized legs of a Z-offset or U-loop.
Use a project-approved allowable displacement stress range Sₐ. Representative moduli and coefficients are constant over the entered temperature range. Confirm temperature-dependent properties, anchor loads, direction of movement, elbow flexibility, fatigue cycles and stress intensification using the governing B31.3 edition and a pipe stress analysis. U-loop width is a layout estimate from the entered aspect ratio.