ASME B31.3 flexibility screen
Stainless transfer line with a Z-offset
A stainless transfer line uses a Z-offset with two equal free legs to take process heat-up.
Inputs
Results
Edit inputs- Movement ΔL
- 163.63mm
- Minimum leg
- 5.69m
- Leg stress
- 324.93MPa
- Stress margin
- -194.93MPa
Increase the free flexing length or revise the routing before detailed flexibility analysis.
Thermal movement and routing
All calculated values
| Temperature change ΔT | 175 °C |
|---|---|
| Signed run movement ΔL | 163.625 mm |
| Motion assigned to each leg | 81.813 mm |
| Minimum flexing leg | 5.692 m |
| Screened displacement stress | 324.93 MPa |
| Available stress range | -194.93 MPa |
| Allowable range used | 249.9 % |
| Nominal elastic modulus | 193 GPa |
| Linear expansion coefficient | 0.000017 1/°C |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Calculate signed pipe movement163.625 mm
- Find the flexing leg length5.692 m
- Compare with available stress range-194.93 MPa
The equal-share model locates a preliminary footprint. Verify guides and elbow flexibility with the pipe stress model.
Model and limits
Use the length between effective anchors and the install-to-operating temperature difference. The guided-cantilever screen assigns the full displacement to a single L-leg or shares it equally across the two idealized legs of a Z-offset or U-loop.
Use a project-approved allowable displacement stress range Sₐ. Representative moduli and coefficients are constant over the entered temperature range. Confirm temperature-dependent properties, anchor loads, direction of movement, elbow flexibility, fatigue cycles and stress intensification using the governing B31.3 edition and a pipe stress analysis. U-loop width is a layout estimate from the entered aspect ratio.
View equations and references