IEC 60534-2-1 / ISA-75.01
Caustic feed with inlet reducers
A metering skid uses a valve smaller than the line, with a provisional Fₚ of 0.83 and specific gravity of 1.26.
Inputs
Results
Edit inputs- Required Cv
- 7.53
- Required Kv
- 6.52
- Choke ΔP
- 74.9psi
- Cavitation σ
- 2.93
The estimated throat pressure and cavitation index are above their onset thresholds. Choking and throat pressure use the bare-valve Fₗ. Enter the OEM Fₗₚ to screen the installed fittings.
Valve pressure recovery
All calculated values
| Required Cv | 7.53 |
|---|---|
| Required Kv | 6.52 |
| Capacity regime | Unchoked |
| Actual pressure drop | 33 psi |
| Choke pressure drop | 74.93 psi |
| Choke recovery basis | Bare-valve Fₗ |
| Effective sizing drop | 33 psi |
| Liquid critical pressure factor Fꜰ | 0.9575 |
| Estimated vena contracta pressure | 54.39 psia |
| Cavitation index σ | 2.932 |
| Actual / choke drop | 44 % |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Find the available drop33 psi
- Limit the drop at choking33 psi
- Size the required Cv7.53
Fitting losses and higher specific gravity increase the required Cv. Replace the provisional factors with vendor data for the valve and reducers.
Model and limits
Use absolute inlet, outlet, vapor and critical pressures for the single-phase turbulent liquid sizing basis. Specific gravity is relative to water. Use vapor pressure at the actual flowing temperature.
Enter matching OEM Fₗₚ and Fₚ for attached fittings. A zero Fₗₚ leaves a bare-valve choke estimate. The pressure profile divides the effective drop by the square of the recovery factor to estimate throat pressure. A low σ or throat pressure indicates cavitation risk. P₂ below Pᵥ indicates flashing. Trim-specific σᵢ, viscous correction, damage limits and multiphase flow require separate review.