IEC 60534-2-1 / ISA-75.01

Caustic feed with inlet reducers

A metering skid uses a valve smaller than the line, with a provisional Fₚ of 0.83 and specific gravity of 1.26.

Inputs

Liquid duty
Trim factors
Use the OEM value with attached fittings. Enter 0 for the bare-valve screen.
Use the OEM value for the selected trim and opening.
Required Cv
7.53
Required Kv
6.52
Choke ΔP
74.9psi
Cavitation σ
2.93
Installed recovery needs review

The estimated throat pressure and cavitation index are above their onset thresholds. Choking and throat pressure use the bare-valve Fₗ. Enter the OEM Fₗₚ to screen the installed fittings.

Valve pressure recovery

Valve pressure recoveryThe pressure profile follows the inlet, vena contracta and outlet. The dashed line is liquid vapor pressure.INLET P₁97 psiaTHROAT Pᵥ꜀54.4 psiaOUTLET P₂64 psiaVAPOR Pᵥ0.25 psiaACTUAL ΔP33 psiCHOKE ΔP74.9 psi
The pressure profile follows the inlet, vena contracta and outlet. The dashed line is liquid vapor pressure.

All calculated values
Required Cv7.53
Required Kv6.52
Capacity regimeUnchoked
Actual pressure drop33 psi
Choke pressure drop74.93 psi
Choke recovery basisBare-valve Fₗ
Effective sizing drop33 psi
Liquid critical pressure factor Fꜰ0.9575
Estimated vena contracta pressure54.39 psia
Cavitation index σ2.932
Actual / choke drop44 %

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Find the available drop33 psi
  2. Limit the drop at choking33 psi
  3. Size the required Cv7.53

Fitting losses and higher specific gravity increase the required Cv. Replace the provisional factors with vendor data for the valve and reducers.

Model and limits

Use absolute inlet, outlet, vapor and critical pressures for the single-phase turbulent liquid sizing basis. Specific gravity is relative to water. Use vapor pressure at the actual flowing temperature.

Enter matching OEM Fₗₚ and Fₚ for attached fittings. A zero Fₗₚ leaves a bare-valve choke estimate. The pressure profile divides the effective drop by the square of the recovery factor to estimate throat pressure. A low σ or throat pressure indicates cavitation risk. P₂ below Pᵥ indicates flashing. Trim-specific σᵢ, viscous correction, damage limits and multiphase flow require separate review.