IEC 60534-2-1 / ISA-75.01
Solvent valve Kv at 18 m³/h
A solvent transfer skid quotes absolute pressure in bar and orders valves by Kv.
Inputs
Results
Edit inputs- Required Cv
- 12.47
- Required Kv
- 10.79
- Choke ΔP
- 436.2kPa
- Cavitation σ
- 2.93
The estimated throat pressure and cavitation index are above their onset thresholds.
Valve pressure recovery
All calculated values
| Required Cv | 12.47 |
|---|---|
| Required Kv | 10.79 |
| Capacity regime | Unchoked |
| Actual pressure drop | 220 kPa |
| Choke pressure drop | 436.15 kPa |
| Choke recovery basis | Bare-valve Fₗ |
| Effective sizing drop | 220 kPa |
| Liquid critical pressure factor Fꜰ | 0.9336 |
| Estimated vena contracta pressure | 3.73 bar abs |
| Cavitation index σ | 2.932 |
| Actual / choke drop | 50.4 % |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Find the available drop220 kPa
- Limit the drop at choking220 kPa
- Size the required Cv12.47
Use the metric coefficient for the vendor comparison. Vapor pressure and specific gravity must match the solvent temperature.
Model and limits
Use absolute inlet, outlet, vapor and critical pressures for the single-phase turbulent liquid sizing basis. Specific gravity is relative to water. Use vapor pressure at the actual flowing temperature.
Enter matching OEM Fₗₚ and Fₚ for attached fittings. A zero Fₗₚ leaves a bare-valve choke estimate. The pressure profile divides the effective drop by the square of the recovery factor to estimate throat pressure. A low σ or throat pressure indicates cavitation risk. P₂ below Pᵥ indicates flashing. Trim-specific σᵢ, viscous correction, damage limits and multiphase flow require separate review.
View equations and references