IEC 60534-2-1 / ISA-75.01
Choked high-recovery liquid trim
A high-recovery rotary trim throttles a liquid with 103 psi of pressure drop. The downstream line is still well above vapor pressure.
Inputs
Results
Edit inputs- Required Cv
- 28.24
- Required Kv
- 24.43
- Choke ΔP
- 55.2psi
- Cavitation σ
- 1.39
Vapor can form at the throat and collapse as static pressure recovers downstream. Choked flow caps the sizing drop.
Valve pressure recovery
All calculated values
| Required Cv | 28.24 |
|---|---|
| Required Kv | 24.43 |
| Capacity regime | Choked |
| Actual pressure drop | 103 psi |
| Choke pressure drop | 55.19 psi |
| Choke recovery basis | Bare-valve Fₗ |
| Effective sizing drop | 55.19 psi |
| Liquid critical pressure factor Fꜰ | 0.9539 |
| Estimated vena contracta pressure | 1.43 psia |
| Cavitation index σ | 1.393 |
| Actual / choke drop | 186.6 % |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Find the available drop103 psi
- Limit the drop at choking55.19 psi
- Size the required Cv28.24
The trim can choke and cavitate while the bulk outlet remains liquid. Check trim staging and erosion risk with the valve supplier.
Model and limits
Use absolute inlet, outlet, vapor and critical pressures for the single-phase turbulent liquid sizing basis. Specific gravity is relative to water. Use vapor pressure at the actual flowing temperature.
Enter matching OEM Fₗₚ and Fₚ for attached fittings. A zero Fₗₚ leaves a bare-valve choke estimate. The pressure profile divides the effective drop by the square of the recovery factor to estimate throat pressure. A low σ or throat pressure indicates cavitation risk. P₂ below Pᵥ indicates flashing. Trim-specific σᵢ, viscous correction, damage limits and multiphase flow require separate review.
View equations and references