IEC 60534-2-1 / ISA-75.01

Incipient cavitation index check

A trim test reports an incipient index of 2.2 for a valve at the planned opening.

Inputs

Liquid duty
Trim factors
Use the OEM value with attached fittings. Enter 0 for the bare-valve screen.
Use the OEM value for the selected trim and opening.
Required Cv
10.87
Required Kv
9.4
Choke ΔP
79.5psi
Cavitation σ
2.06
Cavitation indicated

Vapor can form at the throat and collapse as static pressure recovers downstream.

Valve pressure recovery

Valve pressure recoveryThe pressure profile follows the inlet, vena contracta and outlet. The dashed line is liquid vapor pressure.INLET P₁100 psiaTHROAT Pᵥ꜀41.4 psiaOUTLET P₂52.5 psiaVAPOR Pᵥ2 psiaACTUAL ΔP47.5 psiCHOKE ΔP79.5 psi
The pressure profile follows the inlet, vena contracta and outlet. The dashed line is liquid vapor pressure.

All calculated values
Required Cv10.87
Required Kv9.4
Capacity regimeUnchoked
Actual pressure drop47.5 psi
Choke pressure drop79.46 psi
Choke recovery basisBare-valve Fₗ
Effective sizing drop47.5 psi
Liquid critical pressure factor Fꜰ0.953
Estimated vena contracta pressure41.36 psia
Cavitation index σ2.063
Actual / choke drop59.8 %

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Find the available drop47.5 psi
  2. Limit the drop at choking47.5 psi
  3. Size the required Cv10.87

The entered σᵢ identifies onset before the simplified throat model crosses vapor pressure. Use measured trim-specific limits for final review.

Model and limits

Use absolute inlet, outlet, vapor and critical pressures for the single-phase turbulent liquid sizing basis. Specific gravity is relative to water. Use vapor pressure at the actual flowing temperature.

Enter matching OEM Fₗₚ and Fₚ for attached fittings. A zero Fₗₚ leaves a bare-valve choke estimate. The pressure profile divides the effective drop by the square of the recovery factor to estimate throat pressure. A low σ or throat pressure indicates cavitation risk. P₂ below Pᵥ indicates flashing. Trim-specific σᵢ, viscous correction, damage limits and multiphase flow require separate review.

View equations and references

Worked examples