IEC 60534-2-1 / ISA-75.01

Choked high-recovery liquid trim

A high-recovery rotary trim throttles a liquid with 103 psi of pressure drop. The downstream line is still well above vapor pressure.

Inputs

Liquid duty
Trim factors
Use the OEM value with attached fittings. Enter 0 for the bare-valve screen.
Use the OEM value for the selected trim and opening.
Required Cv
28.24
Required Kv
24.43
Choke ΔP
55.2psi
Cavitation σ
1.39
Cavitation indicated

Vapor can form at the throat and collapse as static pressure recovers downstream. Choked flow caps the sizing drop.

Valve pressure recovery

Valve pressure recoveryThe pressure profile follows the inlet, vena contracta and outlet. The dashed line is liquid vapor pressure.INLET P₁145 psiaTHROAT Pᵥ꜀1.4 psiaOUTLET P₂42 psiaVAPOR Pᵥ1.5 psiaACTUAL ΔP103 psiCHOKE ΔP55.2 psi
The pressure profile follows the inlet, vena contracta and outlet. The dashed line is liquid vapor pressure.

All calculated values
Required Cv28.24
Required Kv24.43
Capacity regimeChoked
Actual pressure drop103 psi
Choke pressure drop55.19 psi
Choke recovery basisBare-valve Fₗ
Effective sizing drop55.19 psi
Liquid critical pressure factor Fꜰ0.9539
Estimated vena contracta pressure1.43 psia
Cavitation index σ1.393
Actual / choke drop186.6 %

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Find the available drop103 psi
  2. Limit the drop at choking55.19 psi
  3. Size the required Cv28.24

The trim can choke and cavitate while the bulk outlet remains liquid. Check trim staging and erosion risk with the valve supplier.

Model and limits

Use absolute inlet, outlet, vapor and critical pressures for the single-phase turbulent liquid sizing basis. Specific gravity is relative to water. Use vapor pressure at the actual flowing temperature.

Enter matching OEM Fₗₚ and Fₚ for attached fittings. A zero Fₗₚ leaves a bare-valve choke estimate. The pressure profile divides the effective drop by the square of the recovery factor to estimate throat pressure. A low σ or throat pressure indicates cavitation risk. P₂ below Pᵥ indicates flashing. Trim-specific σᵢ, viscous correction, damage limits and multiphase flow require separate review.

View equations and references

Worked examples