ISO 5167-2 / ASME MFC-3M

High-beta orifice and recovered pressure

A 154 mm ID line uses a large-bore plate to reduce unrecovered pressure loss at operating flow.

Inputs

Orifice geometry
Flow and fluid
Annual energy
Beta ratio
0.74
Volume flow
132.6m³/h
Meter ΔP
12.5kPa
Permanent ΔP
5.4kPa
Within basic meter screen

β, bore, pipe ID and Re meet the displayed screening bounds. Confirm tapping geometry, the calibrated coefficient and gas expansibility.

Orifice and vena contracta

Orifice and vena contractaThe jet contracts after the plate and then recovers. The permanent loss remains after pressure recovery.PIPE ID D154 mmBORE d114 mmBETA β0.74FLOWPLATEVENA CONTRACTAMETER ΔP12.5 kPaPERMANENT5.4 kPaHEAD LOSS0.56 m
The jet contracts after the plate and then recovers. The permanent loss remains after pressure recovery.

All calculated values
Diameter ratio β0.7403
Upstream volume flow132.58 m³/h
Mass flow36.75 kg/s
Meter differential ΔP12.5 kPa
Combined flow multiplier E1.1955
Pipe Reynolds number303,866
Unrecovered pressure loss5.44 kPa
Unrecovered head0.556 m
Unrecovered share43.5 %
Input power for loss0.286 kW
Annual energy for loss1,860.6 kWh/yr
Annual energy cost223.28 $/yr

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Find the diameter ratio0.7403
  2. Solve the meter equation132.58 m³/h
  3. Keep the unrecovered loss5.44 kPa

The bore is near the upper screening ratio. Confirm the tapping, straight-run and calibration details before selecting the plate.

Model and limits

The screen uses a concentric sharp-edged plate in a full pipe, inlet density, an entered discharge coefficient and expansibility. The default Cd of 0.61 is a screening estimate. Enter a calibrated value or calculate Cd for your tapping geometry. For a liquid, set expansibility to 1. The velocity-of-approach factor is included in E.

The screen uses β from 0.20 to 0.75, pipe ID from 50 to 1,000 mm and bore of at least 12.5 mm. It uses the largest Reynolds floor for corner, D and D/2, and flange tappings. Confirm the actual tapping limits, straight runs, roughness, Cd and gas expansibility. The permanent-loss multiplier is an approximation. Gas volume is at inlet conditions and the energy estimate is a hydraulic power proxy.

View equations and references

Worked examples