ISO 5167-2 / ASME MFC-3M
Nitrogen metering with expansibility correction
A process nitrogen meter uses inlet density and a provisional expansibility coefficient from the metering calculation.
Inputs
Results
Edit inputs- Beta ratio
- 0.49
- Volume flow
- 212.9m³/h
- Meter ΔP
- 11kPa
- Permanent ΔP
- 8.2kPa
β, bore, pipe ID and Re meet the displayed screening bounds. Confirm tapping geometry, the calibrated coefficient and gas expansibility.
Orifice and vena contracta
All calculated values
| Diameter ratio β | 0.4902 |
|---|---|
| Upstream volume flow | 212.87 m³/h |
| Mass flow | 0.54 kg/s |
| Meter differential ΔP | 11 kPa |
| Combined flow multiplier E | 1.0096 |
| Pipe Reynolds number | 377,262 |
| Unrecovered pressure loss | 8.16 kPa |
| Unrecovered head | 90.461 m |
| Unrecovered share | 74.2 % |
| Input power for loss | 0.689 kW |
| Annual energy for loss | 0 kWh/yr |
| Annual energy cost | 0 $/yr |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Find the diameter ratio0.4902
- Solve the meter equation212.87 m³/h
- Keep the unrecovered loss8.16 kPa
Reported volume is at the inlet conditions. Mass flow uses that inlet density, and the energy calculation is disabled for this case.
Model and limits
The screen uses a concentric sharp-edged plate in a full pipe, inlet density, an entered discharge coefficient and expansibility. The default Cd of 0.61 is a screening estimate. Enter a calibrated value or calculate Cd for your tapping geometry. For a liquid, set expansibility to 1. The velocity-of-approach factor is included in E.
The screen uses β from 0.20 to 0.75, pipe ID from 50 to 1,000 mm and bore of at least 12.5 mm. It uses the largest Reynolds floor for corner, D and D/2, and flange tappings. Confirm the actual tapping limits, straight runs, roughness, Cd and gas expansibility. The permanent-loss multiplier is an approximation. Gas volume is at inlet conditions and the energy estimate is a hydraulic power proxy.
View equations and references