ISO 5167-2 / ASME MFC-3M
Viscous liquid below the Reynolds floor
A viscous process liquid runs at low Reynolds number through an existing orifice.
Inputs
Results
Edit inputs- Beta ratio
- 0.529
- Volume flow
- 6.5m³/h
- Meter ΔP
- 4.6kPa
- Permanent ΔP
- 3.2kPa
Re below the conservative tapping screen. Confirm the tap-specific limits before using the flow estimate.
Orifice and vena contracta
All calculated values
| Diameter ratio β | 0.5294 |
|---|---|
| Upstream volume flow | 6.53 m³/h |
| Mass flow | 2.12 kg/s |
| Meter differential ΔP | 4.6 kPa |
| Combined flow multiplier E | 1.0418 |
| Pipe Reynolds number | 248 |
| Unrecovered pressure loss | 3.23 kPa |
| Unrecovered head | 0.281 m |
| Unrecovered share | 70.1 % |
| Input power for loss | 0.008 kW |
| Annual energy for loss | 54.3 kWh/yr |
| Annual energy cost | 6.52 $/yr |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Find the diameter ratio0.5294
- Solve the meter equation6.53 m³/h
- Keep the unrecovered loss3.23 kPa
The basic ISO Reynolds floor is missed. The entered constant discharge coefficient needs validation for this liquid duty.
Model and limits
The screen uses a concentric sharp-edged plate in a full pipe, inlet density, an entered discharge coefficient and expansibility. The default Cd of 0.61 is a screening estimate. Enter a calibrated value or calculate Cd for your tapping geometry. For a liquid, set expansibility to 1. The velocity-of-approach factor is included in E.
The screen uses β from 0.20 to 0.75, pipe ID from 50 to 1,000 mm and bore of at least 12.5 mm. It uses the largest Reynolds floor for corner, D and D/2, and flange tappings. Confirm the actual tapping limits, straight runs, roughness, Cd and gas expansibility. The permanent-loss multiplier is an approximation. Gas volume is at inlet conditions and the energy estimate is a hydraulic power proxy.