ISO 5167-2 / ASME MFC-3M
Orifice loss cost at 8,000 hours per year
A process water train runs most of the year with a known electricity tariff and drive efficiency.
Inputs
Results
Edit inputs- Beta ratio
- 0.61
- Volume flow
- 600.6GPM
- Meter ΔP
- 5psi
- Permanent ΔP
- 3psi
β, bore, pipe ID and Re meet the displayed screening bounds. Confirm tapping geometry, the calibrated coefficient and gas expansibility.
Orifice and vena contracta
All calculated values
| Diameter ratio β | 0.6101 |
|---|---|
| Upstream volume flow | 600.62 GPM |
| Mass flow | 300,142.3 lb/h |
| Meter differential ΔP | 5 psi |
| Combined flow multiplier E | 1.0774 |
| Pipe Reynolds number | 312,562 |
| Unrecovered pressure loss | 3.04 psi |
| Unrecovered head | 7.038 ft |
| Unrecovered share | 60.9 % |
| Input power for loss | 1.263 kW |
| Annual energy for loss | 10,101.8 kWh/yr |
| Annual energy cost | 1,919.34 $/yr |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Find the diameter ratio0.6101
- Solve the meter equation600.62 GPM
- Keep the unrecovered loss3.04 psi
Even a small permanent differential becomes a recurring energy cost. Change hours or efficiency to check sensitivity.
Model and limits
The screen uses a concentric sharp-edged plate in a full pipe, inlet density, an entered discharge coefficient and expansibility. The default Cd of 0.61 is a screening estimate. Enter a calibrated value or calculate Cd for your tapping geometry. For a liquid, set expansibility to 1. The velocity-of-approach factor is included in E.
The screen uses β from 0.20 to 0.75, pipe ID from 50 to 1,000 mm and bore of at least 12.5 mm. It uses the largest Reynolds floor for corner, D and D/2, and flange tappings. Confirm the actual tapping limits, straight runs, roughness, Cd and gas expansibility. The permanent-loss multiplier is an approximation. Gas volume is at inlet conditions and the energy estimate is a hydraulic power proxy.
View equations and references