ISO 5167-2 / ASME MFC-3M
Small-bore plate outside the beta screen
A narrow orifice is proposed to generate a measurable differential in a lightly loaded line.
Inputs
Results
Edit inputs- Beta ratio
- 0.16
- Volume flow
- 3.5m³/h
- Meter ΔP
- 31kPa
- Permanent ΔP
- 30kPa
β outside the 0.20–0.75 screening band. Confirm the tap-specific limits before using the flow estimate.
Orifice and vena contracta
All calculated values
| Diameter ratio β | 0.16 |
|---|---|
| Upstream volume flow | 3.48 m³/h |
| Mass flow | 0.97 kg/s |
| Meter differential ΔP | 31 kPa |
| Combined flow multiplier E | 1.0003 |
| Pipe Reynolds number | 12,288 |
| Unrecovered pressure loss | 30.05 kPa |
| Unrecovered head | 3.07 m |
| Unrecovered share | 96.9 % |
| Input power for loss | 0.042 kW |
| Annual energy for loss | 269.8 kWh/yr |
| Annual energy cost | 32.38 $/yr |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Find the diameter ratio0.16
- Solve the meter equation3.48 m³/h
- Keep the unrecovered loss30.05 kPa
The preview remains calculable while the small diameter ratio prompts a separate applicability check.
Model and limits
The screen uses a concentric sharp-edged plate in a full pipe, inlet density, an entered discharge coefficient and expansibility. The default Cd of 0.61 is a screening estimate. Enter a calibrated value or calculate Cd for your tapping geometry. For a liquid, set expansibility to 1. The velocity-of-approach factor is included in E.
The screen uses β from 0.20 to 0.75, pipe ID from 50 to 1,000 mm and bore of at least 12.5 mm. It uses the largest Reynolds floor for corner, D and D/2, and flange tappings. Confirm the actual tapping limits, straight runs, roughness, Cd and gas expansibility. The permanent-loss multiplier is an approximation. Gas volume is at inlet conditions and the energy estimate is a hydraulic power proxy.
View equations and references