ISO 5167-2 / ASME MFC-3M
Differential for a 480 L/min target
A metering skid needs a differential transmitter range for a known operating flow.
Inputs
Results
Edit inputs- Beta ratio
- 0.577
- Volume flow
- 28.8m³/h
- Meter ΔP
- 30.2kPa
- Permanent ΔP
- 19.6kPa
β, bore, pipe ID and Re meet the displayed screening bounds. Confirm tapping geometry, the calibrated coefficient and gas expansibility.
Orifice and vena contracta
All calculated values
| Diameter ratio β | 0.5769 |
|---|---|
| Upstream volume flow | 28.8 m³/h |
| Mass flow | 7.98 kg/s |
| Meter differential ΔP | 30.17 kPa |
| Combined flow multiplier E | 1.0605 |
| Pipe Reynolds number | 130,327 |
| Unrecovered pressure loss | 19.56 kPa |
| Unrecovered head | 1.999 m |
| Unrecovered share | 64.8 % |
| Input power for loss | 0.241 kW |
| Annual energy for loss | 1,564.9 kWh/yr |
| Annual energy cost | 187.79 $/yr |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Find the diameter ratio0.5769
- Solve the meter equation30.17 kPa
- Keep the unrecovered loss19.56 kPa
The inverse calculation applies the same approach correction and discharge coefficient to find ΔP. Check transmitter turndown separately.
Model and limits
The screen uses a concentric sharp-edged plate in a full pipe, inlet density, an entered discharge coefficient and expansibility. The default Cd of 0.61 is a screening estimate. Enter a calibrated value or calculate Cd for your tapping geometry. For a liquid, set expansibility to 1. The velocity-of-approach factor is included in E.
The screen uses β from 0.20 to 0.75, pipe ID from 50 to 1,000 mm and bore of at least 12.5 mm. It uses the largest Reynolds floor for corner, D and D/2, and flange tappings. Confirm the actual tapping limits, straight runs, roughness, Cd and gas expansibility. The permanent-loss multiplier is an approximation. Gas volume is at inlet conditions and the energy estimate is a hydraulic power proxy.
View equations and references