IEC 60534-2-1 / ISA-75.01
Hot condensate flashing at the outlet
A hot condensate valve discharges to a line where absolute pressure is below the liquid vapor pressure.
Inputs
Results
Edit inputs- Required Cv
- 7.45
- Required Kv
- 6.44
- Choke ΔP
- 47.8psi
- Cavitation σ
- 0.82
Outlet pressure remains below vapor pressure, so vapor can persist beyond the valve. Choked flow caps the sizing drop.
Valve pressure recovery
All calculated values
| Required Cv | 7.45 |
|---|---|
| Required Kv | 6.44 |
| Capacity regime | Choked |
| Actual pressure drop | 85 psi |
| Choke pressure drop | 47.81 psi |
| Choke recovery basis | Bare-valve Fₗ |
| Effective sizing drop | 47.81 psi |
| Liquid critical pressure factor Fꜰ | 0.9217 |
| Estimated vena contracta pressure | 55.3 psia |
| Cavitation index σ | 0.824 |
| Actual / choke drop | 177.8 % |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Find the available drop85 psi
- Limit the drop at choking47.81 psi
- Size the required Cv7.45
Vapor can persist at the outlet. The choked sizing differential limits capacity even as outlet pressure drops farther.
Model and limits
Use absolute inlet, outlet, vapor and critical pressures for the single-phase turbulent liquid sizing basis. Specific gravity is relative to water. Use vapor pressure at the actual flowing temperature.
Enter matching OEM Fₗₚ and Fₚ for attached fittings. A zero Fₗₚ leaves a bare-valve choke estimate. The pressure profile divides the effective drop by the square of the recovery factor to estimate throat pressure. A low σ or throat pressure indicates cavitation risk. P₂ below Pᵥ indicates flashing. Trim-specific σᵢ, viscous correction, damage limits and multiphase flow require separate review.
View equations and references