IEC 60534-2-1 / ISA-75.01
Incipient cavitation index check
A trim test reports an incipient index of 2.2 for a valve at the planned opening.
Inputs
Results
Edit inputs- Required Cv
- 10.87
- Required Kv
- 9.4
- Choke ΔP
- 79.5psi
- Cavitation σ
- 2.06
Vapor can form at the throat and collapse as static pressure recovers downstream.
Valve pressure recovery
All calculated values
| Required Cv | 10.87 |
|---|---|
| Required Kv | 9.4 |
| Capacity regime | Unchoked |
| Actual pressure drop | 47.5 psi |
| Choke pressure drop | 79.46 psi |
| Choke recovery basis | Bare-valve Fₗ |
| Effective sizing drop | 47.5 psi |
| Liquid critical pressure factor Fꜰ | 0.953 |
| Estimated vena contracta pressure | 41.36 psia |
| Cavitation index σ | 2.063 |
| Actual / choke drop | 59.8 % |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Find the available drop47.5 psi
- Limit the drop at choking47.5 psi
- Size the required Cv10.87
The entered σᵢ identifies onset before the simplified throat model crosses vapor pressure. Use measured trim-specific limits for final review.
Model and limits
Use absolute inlet, outlet, vapor and critical pressures for the single-phase turbulent liquid sizing basis. Specific gravity is relative to water. Use vapor pressure at the actual flowing temperature.
Enter matching OEM Fₗₚ and Fₚ for attached fittings. A zero Fₗₚ leaves a bare-valve choke estimate. The pressure profile divides the effective drop by the square of the recovery factor to estimate throat pressure. A low σ or throat pressure indicates cavitation risk. P₂ below Pᵥ indicates flashing. Trim-specific σᵢ, viscous correction, damage limits and multiphase flow require separate review.
View equations and references