IEC 60534-2-1 / ISA-75.01

Solvent valve Kv at 18 m³/h

A solvent transfer skid quotes absolute pressure in bar and orders valves by Kv.

Inputs

Liquid duty
Trim factors
Use the OEM value with attached fittings. Enter 0 for the bare-valve screen.
Use the OEM value for the selected trim and opening.
Required Cv
12.47
Required Kv
10.79
Choke ΔP
436.2kPa
Cavitation σ
2.93
Non-cavitating screen

The estimated throat pressure and cavitation index are above their onset thresholds.

Valve pressure recovery

Valve pressure recoveryThe pressure profile follows the inlet, vena contracta and outlet. The dashed line is liquid vapor pressure.INLET P₁7 bar absTHROAT Pᵥ꜀3.7 bar absOUTLET P₂4.8 bar absVAPOR Pᵥ0.55 bar absACTUAL ΔP220 kPaCHOKE ΔP436.2 kPa
The pressure profile follows the inlet, vena contracta and outlet. The dashed line is liquid vapor pressure.

All calculated values
Required Cv12.47
Required Kv10.79
Capacity regimeUnchoked
Actual pressure drop220 kPa
Choke pressure drop436.15 kPa
Choke recovery basisBare-valve Fₗ
Effective sizing drop220 kPa
Liquid critical pressure factor Fꜰ0.9336
Estimated vena contracta pressure3.73 bar abs
Cavitation index σ2.932
Actual / choke drop50.4 %

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Find the available drop220 kPa
  2. Limit the drop at choking220 kPa
  3. Size the required Cv12.47

Use the metric coefficient for the vendor comparison. Vapor pressure and specific gravity must match the solvent temperature.

Model and limits

Use absolute inlet, outlet, vapor and critical pressures for the single-phase turbulent liquid sizing basis. Specific gravity is relative to water. Use vapor pressure at the actual flowing temperature.

Enter matching OEM Fₗₚ and Fₚ for attached fittings. A zero Fₗₚ leaves a bare-valve choke estimate. The pressure profile divides the effective drop by the square of the recovery factor to estimate throat pressure. A low σ or throat pressure indicates cavitation risk. P₂ below Pᵥ indicates flashing. Trim-specific σᵢ, viscous correction, damage limits and multiphase flow require separate review.

View equations and references