ISO 5167-2 / ASME MFC-3M

Nitrogen metering with expansibility correction

A process nitrogen meter uses inlet density and a provisional expansibility coefficient from the metering calculation.

Inputs

Orifice geometry
Flow and fluid
Annual energy
Beta ratio
0.49
Volume flow
212.9m³/h
Meter ΔP
11kPa
Permanent ΔP
8.2kPa
Within basic meter screen

β, bore, pipe ID and Re meet the displayed screening bounds. Confirm tapping geometry, the calibrated coefficient and gas expansibility.

Orifice and vena contracta

Orifice and vena contractaThe jet contracts after the plate and then recovers. The permanent loss remains after pressure recovery.PIPE ID D102 mmBORE d50 mmBETA β0.49FLOWPLATEVENA CONTRACTAMETER ΔP11 kPaPERMANENT8.2 kPaHEAD LOSS90.46 m
The jet contracts after the plate and then recovers. The permanent loss remains after pressure recovery.

All calculated values
Diameter ratio β0.4902
Upstream volume flow212.87 m³/h
Mass flow0.54 kg/s
Meter differential ΔP11 kPa
Combined flow multiplier E1.0096
Pipe Reynolds number377,262
Unrecovered pressure loss8.16 kPa
Unrecovered head90.461 m
Unrecovered share74.2 %
Input power for loss0.689 kW
Annual energy for loss0 kWh/yr
Annual energy cost0 $/yr

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Find the diameter ratio0.4902
  2. Solve the meter equation212.87 m³/h
  3. Keep the unrecovered loss8.16 kPa

Reported volume is at the inlet conditions. Mass flow uses that inlet density, and the energy calculation is disabled for this case.

Model and limits

The screen uses a concentric sharp-edged plate in a full pipe, inlet density, an entered discharge coefficient and expansibility. The default Cd of 0.61 is a screening estimate. Enter a calibrated value or calculate Cd for your tapping geometry. For a liquid, set expansibility to 1. The velocity-of-approach factor is included in E.

The screen uses β from 0.20 to 0.75, pipe ID from 50 to 1,000 mm and bore of at least 12.5 mm. It uses the largest Reynolds floor for corner, D and D/2, and flange tappings. Confirm the actual tapping limits, straight runs, roughness, Cd and gas expansibility. The permanent-loss multiplier is an approximation. Gas volume is at inlet conditions and the energy estimate is a hydraulic power proxy.

View equations and references