ISO 5167-2 / ASME MFC-3M

Orifice loss cost at 8,000 hours per year

A process water train runs most of the year with a known electricity tariff and drive efficiency.

Inputs

Orifice geometry
Flow and fluid
Annual energy
Beta ratio
0.61
Volume flow
600.6GPM
Meter ΔP
5psi
Permanent ΔP
3psi
Within basic meter screen

β, bore, pipe ID and Re meet the displayed screening bounds. Confirm tapping geometry, the calibrated coefficient and gas expansibility.

Orifice and vena contracta

Orifice and vena contractaThe jet contracts after the plate and then recovers. The permanent loss remains after pressure recovery.PIPE ID D6.07 inBORE d3.7 inBETA β0.61FLOWPLATEVENA CONTRACTAMETER ΔP5 psiPERMANENT3 psiHEAD LOSS7.04 ft
The jet contracts after the plate and then recovers. The permanent loss remains after pressure recovery.

All calculated values
Diameter ratio β0.6101
Upstream volume flow600.62 GPM
Mass flow300,142.3 lb/h
Meter differential ΔP5 psi
Combined flow multiplier E1.0774
Pipe Reynolds number312,562
Unrecovered pressure loss3.04 psi
Unrecovered head7.038 ft
Unrecovered share60.9 %
Input power for loss1.263 kW
Annual energy for loss10,101.8 kWh/yr
Annual energy cost1,919.34 $/yr

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Find the diameter ratio0.6101
  2. Solve the meter equation600.62 GPM
  3. Keep the unrecovered loss3.04 psi

Even a small permanent differential becomes a recurring energy cost. Change hours or efficiency to check sensitivity.

Model and limits

The screen uses a concentric sharp-edged plate in a full pipe, inlet density, an entered discharge coefficient and expansibility. The default Cd of 0.61 is a screening estimate. Enter a calibrated value or calculate Cd for your tapping geometry. For a liquid, set expansibility to 1. The velocity-of-approach factor is included in E.

The screen uses β from 0.20 to 0.75, pipe ID from 50 to 1,000 mm and bore of at least 12.5 mm. It uses the largest Reynolds floor for corner, D and D/2, and flange tappings. Confirm the actual tapping limits, straight runs, roughness, Cd and gas expansibility. The permanent-loss multiplier is an approximation. Gas volume is at inlet conditions and the energy estimate is a hydraulic power proxy.

View equations and references

Worked examples