ISO 5167-2 / ASME MFC-3M

Differential for a 480 L/min target

A metering skid needs a differential transmitter range for a known operating flow.

Inputs

Orifice geometry
Flow and fluid
Annual energy
Beta ratio
0.577
Volume flow
28.8m³/h
Meter ΔP
30.2kPa
Permanent ΔP
19.6kPa
Within basic meter screen

β, bore, pipe ID and Re meet the displayed screening bounds. Confirm tapping geometry, the calibrated coefficient and gas expansibility.

Orifice and vena contracta

Orifice and vena contractaThe jet contracts after the plate and then recovers. The permanent loss remains after pressure recovery.PIPE ID D78 mmBORE d45 mmBETA β0.577FLOWPLATEVENA CONTRACTAMETER ΔP30.2 kPaPERMANENT19.6 kPaHEAD LOSS2 m
The jet contracts after the plate and then recovers. The permanent loss remains after pressure recovery.

All calculated values
Diameter ratio β0.5769
Upstream volume flow28.8 m³/h
Mass flow7.98 kg/s
Meter differential ΔP30.17 kPa
Combined flow multiplier E1.0605
Pipe Reynolds number130,327
Unrecovered pressure loss19.56 kPa
Unrecovered head1.999 m
Unrecovered share64.8 %
Input power for loss0.241 kW
Annual energy for loss1,564.9 kWh/yr
Annual energy cost187.79 $/yr

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Find the diameter ratio0.5769
  2. Solve the meter equation30.17 kPa
  3. Keep the unrecovered loss19.56 kPa

The inverse calculation applies the same approach correction and discharge coefficient to find ΔP. Check transmitter turndown separately.

Model and limits

The screen uses a concentric sharp-edged plate in a full pipe, inlet density, an entered discharge coefficient and expansibility. The default Cd of 0.61 is a screening estimate. Enter a calibrated value or calculate Cd for your tapping geometry. For a liquid, set expansibility to 1. The velocity-of-approach factor is included in E.

The screen uses β from 0.20 to 0.75, pipe ID from 50 to 1,000 mm and bore of at least 12.5 mm. It uses the largest Reynolds floor for corner, D and D/2, and flange tappings. Confirm the actual tapping limits, straight runs, roughness, Cd and gas expansibility. The permanent-loss multiplier is an approximation. Gas volume is at inlet conditions and the energy estimate is a hydraulic power proxy.

View equations and references

Worked examples