ASME B31.3 flexibility screen

U-loop with constrained leg height

A hot header crosses a crowded pipe rack that limits the available loop height to five feet.

Inputs

Thermal duty
Flexibility screen
Movement ΔL
7.04in
Minimum leg
23.06ft
Leg stress
382.9ksi
Stress margin
-364.9ksi
Leg stress exceeds Sₐ

Increase the free flexing length or revise the routing before detailed flexibility analysis.

Thermal movement and routing

Thermal movement and routingArrows indicate the direction of thermal movement. The routed legs and dimensions represent the selected layout.RUN ΔL7.04 inLOOP WIDTH5.5 ftWHFLEXING PIPEMIN. LEG23.06 ftPROVIDED LEG5 ftSTRESS MARGIN-364.9 ksi
Arrows indicate the direction of thermal movement. The routed legs and dimensions represent the selected layout.

All calculated values
Temperature change ΔT400 °F
Signed run movement ΔL7.04 in
Motion assigned to each leg3.52 in
Minimum flexing leg23.061 ft
Width at minimum U-loop height25.367 ft
Width at provided U-loop height5.5 ft
Screened displacement stress382.9 ksi
Available stress range-364.9 ksi
Allowable range used2,127.2 %
Nominal elastic modulus29.01 Mpsi
Linear expansion coefficient0.000012 1/°C

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Calculate signed pipe movement7.04 in
  2. Find the flexing leg length23.061 ft
  3. Compare with available stress range-364.9 ksi

The provided leg exceeds the screened displacement stress range. An alternate framing layout or full flexibility model is needed.

Model and limits

Use the length between effective anchors and the install-to-operating temperature difference. The guided-cantilever screen assigns the full displacement to a single L-leg or shares it equally across the two idealized legs of a Z-offset or U-loop.

Use a project-approved allowable displacement stress range Sₐ. Representative moduli and coefficients are constant over the entered temperature range. Confirm temperature-dependent properties, anchor loads, direction of movement, elbow flexibility, fatigue cycles and stress intensification using the governing B31.3 edition and a pipe stress analysis. U-loop width is a layout estimate from the entered aspect ratio.

View equations and references