ISO 5167-2 / ASME MFC-3M

Small-bore plate outside the beta screen

A narrow orifice is proposed to generate a measurable differential in a lightly loaded line.

Inputs

Orifice geometry
Flow and fluid
Annual energy
Beta ratio
0.16
Volume flow
3.5m³/h
Meter ΔP
31kPa
Permanent ΔP
30kPa
Meter applicability review

β outside the 0.20–0.75 screening band. Confirm the tap-specific limits before using the flow estimate.

Orifice and vena contracta

Orifice and vena contractaThe jet contracts after the plate and then recovers. The permanent loss remains after pressure recovery.PIPE ID D100 mmBORE d16 mmBETA β0.16FLOWPLATEVENA CONTRACTAMETER ΔP31 kPaPERMANENT30 kPaHEAD LOSS3.07 m
The jet contracts after the plate and then recovers. The permanent loss remains after pressure recovery.

All calculated values
Diameter ratio β0.16
Upstream volume flow3.48 m³/h
Mass flow0.97 kg/s
Meter differential ΔP31 kPa
Combined flow multiplier E1.0003
Pipe Reynolds number12,288
Unrecovered pressure loss30.05 kPa
Unrecovered head3.07 m
Unrecovered share96.9 %
Input power for loss0.042 kW
Annual energy for loss269.8 kWh/yr
Annual energy cost32.38 $/yr

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Find the diameter ratio0.16
  2. Solve the meter equation3.48 m³/h
  3. Keep the unrecovered loss30.05 kPa

The preview remains calculable while the small diameter ratio prompts a separate applicability check.

Model and limits

The screen uses a concentric sharp-edged plate in a full pipe, inlet density, an entered discharge coefficient and expansibility. The default Cd of 0.61 is a screening estimate. Enter a calibrated value or calculate Cd for your tapping geometry. For a liquid, set expansibility to 1. The velocity-of-approach factor is included in E.

The screen uses β from 0.20 to 0.75, pipe ID from 50 to 1,000 mm and bore of at least 12.5 mm. It uses the largest Reynolds floor for corner, D and D/2, and flange tappings. Confirm the actual tapping limits, straight runs, roughness, Cd and gas expansibility. The permanent-loss multiplier is an approximation. Gas volume is at inlet conditions and the energy estimate is a hydraulic power proxy.

View equations and references

Worked examples