ISO 5167-2 / ASME MFC-3M

Viscous liquid below the Reynolds floor

A viscous process liquid runs at low Reynolds number through an existing orifice.

Inputs

Orifice geometry
Flow and fluid
Annual energy
Beta ratio
0.529
Volume flow
6.5m³/h
Meter ΔP
4.6kPa
Permanent ΔP
3.2kPa
Meter applicability review

Re below the conservative tapping screen. Confirm the tap-specific limits before using the flow estimate.

Orifice and vena contracta

Orifice and vena contractaThe jet contracts after the plate and then recovers. The permanent loss remains after pressure recovery.PIPE ID D68 mmBORE d36 mmBETA β0.529FLOWPLATEVENA CONTRACTAMETER ΔP4.6 kPaPERMANENT3.2 kPaHEAD LOSS0.28 m
The jet contracts after the plate and then recovers. The permanent loss remains after pressure recovery.

All calculated values
Diameter ratio β0.5294
Upstream volume flow6.53 m³/h
Mass flow2.12 kg/s
Meter differential ΔP4.6 kPa
Combined flow multiplier E1.0418
Pipe Reynolds number248
Unrecovered pressure loss3.23 kPa
Unrecovered head0.281 m
Unrecovered share70.1 %
Input power for loss0.008 kW
Annual energy for loss54.3 kWh/yr
Annual energy cost6.52 $/yr

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Find the diameter ratio0.5294
  2. Solve the meter equation6.53 m³/h
  3. Keep the unrecovered loss3.23 kPa

The basic ISO Reynolds floor is missed. The entered constant discharge coefficient needs validation for this liquid duty.

Model and limits

The screen uses a concentric sharp-edged plate in a full pipe, inlet density, an entered discharge coefficient and expansibility. The default Cd of 0.61 is a screening estimate. Enter a calibrated value or calculate Cd for your tapping geometry. For a liquid, set expansibility to 1. The velocity-of-approach factor is included in E.

The screen uses β from 0.20 to 0.75, pipe ID from 50 to 1,000 mm and bore of at least 12.5 mm. It uses the largest Reynolds floor for corner, D and D/2, and flange tappings. Confirm the actual tapping limits, straight runs, roughness, Cd and gas expansibility. The permanent-loss multiplier is an approximation. Gas volume is at inlet conditions and the energy estimate is a hydraulic power proxy.

View equations and references

Worked examples