IEC 60534-2-1 / ISA-75.01
Liquid control valve Cv calculator
Size a liquid control valve for the specified flow and pressure drop. Check choked capacity, cavitation and flashing on the pressure-recovery profile.
Inputs
Results
Edit inputs- Required Cv
- 18.95
- Required Kv
- 16.4
- Choke ΔP
- 79.2psi
- Cavitation σ
- 2.74
The estimated throat pressure and cavitation index are above their onset thresholds.
Valve pressure recovery
All calculated values
| Required Cv | 18.95 |
|---|---|
| Required Kv | 16.4 |
| Capacity regime | Unchoked |
| Actual pressure drop | 40 psi |
| Choke pressure drop | 79.16 psi |
| Choke recovery basis | Bare-valve Fₗ |
| Effective sizing drop | 40 psi |
| Liquid critical pressure factor Fꜰ | 0.9566 |
| Estimated vena contracta pressure | 54.64 psia |
| Cavitation index σ | 2.739 |
| Actual / choke drop | 50.5 % |
Model and limits
Use absolute inlet, outlet, vapor and critical pressures for the single-phase turbulent liquid sizing basis. Specific gravity is relative to water. Use vapor pressure at the actual flowing temperature.
Enter matching OEM Fₗₚ and Fₚ for attached fittings. A zero Fₗₚ leaves a bare-valve choke estimate. The pressure profile divides the effective drop by the square of the recovery factor to estimate throat pressure. A low σ or throat pressure indicates cavitation risk. P₂ below Pᵥ indicates flashing. Trim-specific σᵢ, viscous correction, damage limits and multiphase flow require separate review.