IEC 60534-2-1 / ISA-75.01

Liquid control valve Cv calculator

Size a liquid control valve for the specified flow and pressure drop. Check choked capacity, cavitation and flashing on the pressure-recovery profile.

Inputs

Liquid duty
Trim factors
Use the OEM value with attached fittings. Enter 0 for the bare-valve screen.
Use the OEM value for the selected trim and opening.
Required Cv
18.95
Required Kv
16.4
Choke ΔP
79.2psi
Cavitation σ
2.74
Non-cavitating screen

The estimated throat pressure and cavitation index are above their onset thresholds.

Valve pressure recovery

Valve pressure recoveryThe pressure profile follows the inlet, vena contracta and outlet. The dashed line is liquid vapor pressure.INLET P₁110 psiaTHROAT Pᵥ꜀54.6 psiaOUTLET P₂70 psiaVAPOR Pᵥ0.46 psiaACTUAL ΔP40 psiCHOKE ΔP79.2 psi
The pressure profile follows the inlet, vena contracta and outlet. The dashed line is liquid vapor pressure.

All calculated values
Required Cv18.95
Required Kv16.4
Capacity regimeUnchoked
Actual pressure drop40 psi
Choke pressure drop79.16 psi
Choke recovery basisBare-valve Fₗ
Effective sizing drop40 psi
Liquid critical pressure factor Fꜰ0.9566
Estimated vena contracta pressure54.64 psia
Cavitation index σ2.739
Actual / choke drop50.5 %

Model and limits

Use absolute inlet, outlet, vapor and critical pressures for the single-phase turbulent liquid sizing basis. Specific gravity is relative to water. Use vapor pressure at the actual flowing temperature.

Enter matching OEM Fₗₚ and Fₚ for attached fittings. A zero Fₗₚ leaves a bare-valve choke estimate. The pressure profile divides the effective drop by the square of the recovery factor to estimate throat pressure. A low σ or throat pressure indicates cavitation risk. P₂ below Pᵥ indicates flashing. Trim-specific σᵢ, viscous correction, damage limits and multiphase flow require separate review.

View equations and references

Worked examples