ISO 5167-2 / ASME MFC-3M
Orifice plate flowmeter calculator
Solve liquid or single-phase flow from measured differential pressure, or work backward from target flow. Estimate permanent head loss and annual energy cost.
Inputs
Results
Edit inputs- Beta ratio
- 0.596
- Volume flow
- 194.4GPM
- Meter ΔP
- 3psi
- Permanent ΔP
- 1.9psi
β, bore, pipe ID and Re meet the displayed screening bounds. Confirm tapping geometry, the calibrated coefficient and gas expansibility.
Orifice and vena contracta
All calculated values
| Diameter ratio β | 0.5961 |
|---|---|
| Upstream volume flow | 194.37 GPM |
| Mass flow | 97,131.87 lb/h |
| Meter differential ΔP | 3 psi |
| Combined flow multiplier E | 1.0698 |
| Pipe Reynolds number | 152,380 |
| Unrecovered pressure loss | 1.88 psi |
| Unrecovered head | 4.339 ft |
| Unrecovered share | 62.6 % |
| Input power for loss | 0.227 kW |
| Annual energy for loss | 1,473.9 kWh/yr |
| Annual energy cost | 176.87 $/yr |
Model and limits
The screen uses a concentric sharp-edged plate in a full pipe, inlet density, an entered discharge coefficient and expansibility. The default Cd of 0.61 is a screening estimate. Enter a calibrated value or calculate Cd for your tapping geometry. For a liquid, set expansibility to 1. The velocity-of-approach factor is included in E.
The screen uses β from 0.20 to 0.75, pipe ID from 50 to 1,000 mm and bore of at least 12.5 mm. It uses the largest Reynolds floor for corner, D and D/2, and flange tappings. Confirm the actual tapping limits, straight runs, roughness, Cd and gas expansibility. The permanent-loss multiplier is an approximation. Gas volume is at inlet conditions and the energy estimate is a hydraulic power proxy.
View equations and references