Attic Ventilation NFA, Ridge Vent & Soffit Calculator

Calculate total net free area and compare the installed low intake with ridge, box or turbine exhaust.

Inputs

Units
Ventilation target
ft²
Low intake
in²
High exhaust
ft
in²/ft

Results

Live

Low intake and high exhaust balanceRequired total NFA 1,344 in². Target per vent group 672 in². RIDGEIntakeExhaust672 in²648 in²
Low intake and high exhaust balance Schematic
Installed low intake
672 in²
Installed high exhaust
648 in²
Installed total NFA
1,320 in²
Balanced NFA equivalent
1,296 in²
Upper share of installed NFA
49.09%
Intake shortfall
0 in²
Exhaust shortfall
24 in²
Total soffit vent units needed
12
Total active ridge vent needed
37.33 ft
Additional soffit units
0
Additional active ridge vent
1.33 ft
  • One or both vent groups are below the 50/50 planning target.

Balance low intake and high exhaust

  1. Use the floor area of the connected vented space. Divide by 150 or 300, then express the result as net free area. Each group has a 50% planning target.
  2. Multiply installed vent counts by per-unit NFA, or the active ridge length by its NFA rating per unit length. The yellow marks in the diagram represent the target for each group.
  3. Compare intake and exhaust separately. The balanced equivalent is twice the smaller group, which helps show what is lost when one group is restricted.

Use the 1:300 ratio only where the adopted code permits it. Placement and applicable vapor-retarder conditions matter. Confirm unobstructed intake pathways, the specified upper-vent distribution and the vent assembly ratings.

References

Frequently asked questions

What does attic vent net free area measure?

NFA is the open area available for air to pass after accounting for screens, louvers and other vent parts. Use a documented rating.

How are soffit and ridge vents checked against each other?

Compare both installed NFA totals and the 50/50 targets. Excess high exhaust can leave a system limited by low intake.

Does the attic tool estimate airflow in cubic feet per minute?

It sizes openings by net free area. Actual airflow depends on pressure, temperature differences, wind and vent geometry.