Ventilation check with only 20 ft of ridge
A 1,600 ft² attic has a short active ridge and 18 in² of documented ridge NFA per foot.
Worked calculation
The ridge delivers 360 in² and the high-side target is 768 in². The resulting 408 in² gap is the equivalent of about 22.67 additional feet at the same rating.
Change the inputs to test your own measurements. Reset restores this example.
Results
LiveCorrect the highlighted inputs to update your results.
- Required total NFA
- Target per vent group
- Installed low intake
- Installed high exhaust
- Installed total NFA
- Balanced NFA equivalent
- Upper share of installed NFA
- Intake shortfall
- Exhaust shortfall
- Total soffit vent units needed
- Total active ridge vent needed
- Additional soffit units
- Additional active ridge vent
- One or both vent groups are below the 50/50 planning target.
Worksheet inputs US customary
- Vented attic floor area
- 1,600 ft²
- Ventilation ratio
- 1:150 · baseline
- Soffit vent units
- 15
- Net free area per soffit vent
- 56 in²
- Exhaust system
- Continuous ridge vent
- Active ridge vent length
- 20 ft
- Ridge vent NFA per length
- 18 in²/ft
Apply this example to your roof
Use the 1:300 ratio only where the adopted code permits it. Placement and applicable vapor-retarder conditions matter. Confirm unobstructed intake pathways, the specified upper-vent distribution and the vent assembly ratings.
Frequently asked questions
Is a 20-foot ridge enough for this 1,600 ft² attic?
At the entered rating and ratio, it covers 360 of the 768 in² high-side target. Review another suitable high exhaust layout.
Why can active ridge vent length be shorter than the ridge cap?
End setbacks, blocked slots and unvented sections reduce the continuous opening that contributes NFA.