1:300 planning case for a 1,800 ft² attic
An attic design is being evaluated for the reduced 1:300 ratio. Test a 24 ft active ridge with 12 soffit vents.
Worked calculation
The total target is 864 in². This layout has 432 in² at the ridge and 504 in² low. The installed upper share is about 46.15%.
Change the inputs to test your own measurements. Reset restores this example.
Results
LiveCorrect the highlighted inputs to update your results.
- Required total NFA
- Target per vent group
- Installed low intake
- Installed high exhaust
- Installed total NFA
- Balanced NFA equivalent
- Upper share of installed NFA
- Intake shortfall
- Exhaust shortfall
- Total soffit vent units needed
- Total active ridge vent needed
- Additional soffit units
- Additional active ridge vent
- Verify eligibility for 1:300 under the adopted code, including upper-vent distribution and applicable vapor-retarder conditions.
Worksheet inputs US customary
- Vented attic floor area
- 1,800 ft²
- Ventilation ratio
- 1:300 · where permitted
- Soffit vent units
- 12
- Net free area per soffit vent
- 42 in²
- Exhaust system
- Continuous ridge vent
- Active ridge vent length
- 24 ft
- Ridge vent NFA per length
- 18 in²/ft
Apply this example to your roof
Use the 1:300 ratio only where the adopted code permits it. Placement and applicable vapor-retarder conditions matter. Confirm unobstructed intake pathways, the specified upper-vent distribution and the vent assembly ratings.
Frequently asked questions
What upper vent share does the 24-foot ridge give here?
Its 432 in² of NFA is about 46.15% of the installed 936 in² total.
Does the 46% upper share alone establish 1:300 eligibility?
Check the applicable adopted code, placement distances and climate-zone vapor-retarder conditions as well.