Turbine exhaust with undersized soffit intake

An attic has four turbines with a rated 150 in² opening each and eight soffit vents rated at 50 in² apiece.

Worked calculation

The exhaust group has 600 in², while intake has 400 in². For the 720 in² intake target, the 320 in² shortfall takes seven more 50 in² units.

Change the inputs to test your own measurements. Reset restores this example.

Inputs

Units
Ventilation target
ft²
Low intake
in²
High exhaust
in²

Results

Live

Low intake and high exhaust balanceRequired total NFA 1,440 in². Target per vent group 720 in². TURBINESIntakeExhaust400 in²600 in²
Low intake and high exhaust balance Schematic
Installed low intake
400 in²
Installed high exhaust
600 in²
Installed total NFA
1,000 in²
Balanced NFA equivalent
800 in²
Upper share of installed NFA
60%
Intake shortfall
320 in²
Exhaust shortfall
120 in²
Total soffit vent units needed
15
Total high exhaust units needed
5
Additional soffit units
7
Additional high exhaust units
1
  • High exhaust exceeds the low intake NFA. Add or clear low intake before relying on the exhaust rating.
  • One or both vent groups are below the 50/50 planning target.

Apply this example to your roof

Use the 1:300 ratio only where the adopted code permits it. Placement and applicable vapor-retarder conditions matter. Confirm unobstructed intake pathways, the specified upper-vent distribution and the vent assembly ratings.

Read the calculator method and references

Frequently asked questions

Will adding a fifth turbine fix this attic’s intake shortfall?

Increase or clear low intake first. An additional turbine increases the high exhaust rating while the low intake gap stays at 320 in².

Which turbine rating belongs in an NFA estimate?

Use the documented net free area for the vent assembly. A powered airflow or CFM rating measures something different.