Worked example · Hydrology
Initial abstraction sensitivity for a small storm
Water is collected from connected paved surfaces and adjacent grass during a moderate event. Start at λ = 0.05 for a sensitivity comparison.
Inputs
Rainfall partition
Live resultsPost-development runoff increases
The volume change is post-development minus pre-development.
Calculation results
- Post runoff
- 0.65 in
- Pre runoff
- 0.27 in
- Volume change
- 0.138 acre-ft
- Post CN
- 84.7
- Pre-development CN
- 67.1
- Drainage area
- 4.4 acre
- Pre retention
- 4.9 in
- Post retention
- 1.81 in
- Pre initial abstraction
- 0.25 in
- Post initial abstraction
- 0.09 in
- Pre runoff volume
- 0.101 acre-ft
- Post runoff volume
- 0.239 acre-ft
- Runoff depth change
- 0.38 in
Worked calculation
Switch to 0.20 and compare both runoff depths. For a design comparison, use CN values fitted to each abstraction ratio.
S = 1000/CN − 10 (inches) · Iₐ = λS · Qd = (P − Iₐ)²/(P − Iₐ + S) for P > Iₐ, else 0.
The 0.20 option follows TR-55. The 0.05 option evaluates the entered CN values as supplied. For design with 0.05, use curve numbers calibrated to that choice. Weighted CN is evaluated before the nonlinear runoff equation. For strongly mixed or hydraulically disconnected cover, consider separate runoff calculations.
More worked examples
Open the main calculatorInitial abstraction sensitivity for a small storm
Inputs
- Zone 1 area
- 2.1 acre
- Zone 1 pre-development CN
- 76
- Zone 1 post-development CN
- 92
- Zone 2 area
- 2.3 acre
- Zone 2 pre-development CN
- 59
- Zone 2 post-development CN
- 78
- Zone 3 area
- 0 acre
- Zone 3 pre-development CN
- 74
- Zone 3 post-development CN
- 74
- Event rainfall
- 1.55 in
- Initial abstraction
- 0.05 S · sensitivity
Results
- Post runoff
- 0.65 in
- Pre runoff
- 0.27 in
- Volume change
- 0.138 acre-ft
- Post CN
- 84.7
- Pre-development CN
- 67.1
- Drainage area
- 4.4 acre
- Pre retention
- 4.9 in
- Post retention
- 1.81 in
- Pre initial abstraction
- 0.25 in
- Post initial abstraction
- 0.09 in
- Pre runoff volume
- 0.101 acre-ft
- Post runoff volume
- 0.239 acre-ft
- Runoff depth change
- 0.38 in
Post-development runoff increases
The volume change is post-development minus pre-development.
S = 1000/CN − 10 (inches) · Iₐ = λS · Qd = (P − Iₐ)²/(P − Iₐ + S) for P > Iₐ, else 0.
Screening worksheet · Verify design using project criteria and site data.