Worked example · Hydrology

Meadow runoff during a deep design storm

An existing meadow and adjoining woodland drain from a moderate-size watershed. Enter the same curve number before and after to study a baseline event.

Inputs

Drainage zones
ZoneArea (acre)Pre CNPost CN
Zone 1
0–5,000 acre
30–98
30–98
Zone 2
0–5,000 acre
30–98
30–98
Zone 3
0–5,000 acre
30–98
30–98

Keep each zone footprint the same across both conditions. Subdivide cover where needed and use zero area for unused zones.

Rainfall event
0–60 in

Match the curve numbers to the selected abstraction convention.

Rainfall partition

Live results
Rainfall partition Runoff is unchanged. The volume change is post-development minus pre-development. POST RUNOFF 3.07 in PRE RUNOFF 3.07 in VOLUME CHANGE 0 acre-ft POST CN 66.3 Event rain6.8 in3.07 inExisting3.07 inDeveloped 0% · retainedPost runoff share100% · runoff

Runoff is unchanged

The volume change is post-development minus pre-development.

Calculation results

Post runoff
3.07 in
Pre runoff
3.07 in
Volume change
0 acre-ft
Post CN
66.3
Pre-development CN
66.3
Drainage area
49 acre
Pre retention
5.09 in
Post retention
5.09 in
Pre initial abstraction
1.02 in
Post initial abstraction
1.02 in
Pre runoff volume
12.555 acre-ft
Post runoff volume
12.555 acre-ft
Runoff depth change
0 in

Worked calculation

The depth and volume deltas should equal zero. Change the rainfall to see how the runoff fraction increases with storm depth.

S = 1000/CN − 10 (inches) · Iₐ = λS · Qd = (P − Iₐ)²/(P − Iₐ + S) for P > Iₐ, else 0.

The 0.20 option follows TR-55. The 0.05 option evaluates the entered CN values as supplied. For design with 0.05, use curve numbers calibrated to that choice. Weighted CN is evaluated before the nonlinear runoff equation. For strongly mixed or hydraulically disconnected cover, consider separate runoff calculations.

Open the main calculator

Share this calculation

This link opens the worksheet with your current inputs and units.