Worked example · Hydrology

Initial abstraction sensitivity for a small storm

Water is collected from connected paved surfaces and adjacent grass during a moderate event. Start at λ = 0.05 for a sensitivity comparison.

Inputs

Drainage zones
ZoneArea (acre)Pre CNPost CN
Zone 1
0–5,000 acre
30–98
30–98
Zone 2
0–5,000 acre
30–98
30–98
Zone 3
0–5,000 acre
30–98
30–98

Keep each zone footprint the same across both conditions. Subdivide cover where needed and use zero area for unused zones.

Rainfall event
0–60 in

Match the curve numbers to the selected abstraction convention.

Rainfall partition

Live results
Rainfall partition Post-development runoff increases. The volume change is post-development minus pre-development. POST RUNOFF 0.65 in PRE RUNOFF 0.27 in VOLUME CHANGE 0.138 acre-ft POST CN 84.7 Event rain1.55 in0.27 inExisting0.65 inDeveloped 0% · retainedPost runoff share100% · runoff

Post-development runoff increases

The volume change is post-development minus pre-development.

Calculation results

Post runoff
0.65 in
Pre runoff
0.27 in
Volume change
0.138 acre-ft
Post CN
84.7
Pre-development CN
67.1
Drainage area
4.4 acre
Pre retention
4.9 in
Post retention
1.81 in
Pre initial abstraction
0.25 in
Post initial abstraction
0.09 in
Pre runoff volume
0.101 acre-ft
Post runoff volume
0.239 acre-ft
Runoff depth change
0.38 in

Worked calculation

Switch to 0.20 and compare both runoff depths. For a design comparison, use CN values fitted to each abstraction ratio.

S = 1000/CN − 10 (inches) · Iₐ = λS · Qd = (P − Iₐ)²/(P − Iₐ + S) for P > Iₐ, else 0.

The 0.20 option follows TR-55. The 0.05 option evaluates the entered CN values as supplied. For design with 0.05, use curve numbers calibrated to that choice. Weighted CN is evaluated before the nonlinear runoff equation. For strongly mixed or hydraulically disconnected cover, consider separate runoff calculations.

Open the main calculator

Share this calculation

This link opens the worksheet with your current inputs and units.