HEC-14 five-foot culvert riprap apron

Reproduce the customary-unit HEC-14 example for a 60 in circular outlet passing 85 cfs with 1.6 ft tailwater.

Inputs

Culvert outfall
0–1,500 cfs
6–144 in
0–20 ft

For unknown tailwater enter zero. The HEC-14 minimum is applied automatically.

Stone and placement
0–60 in
2–4
40–200 lb/ft³

Use in-place bulk density, including voids, for material tonnage.

Riprap apron plan

Live results
Riprap apron plan Available stone meets D₅₀. Low tailwater (TW < 0.5Dₒ). Example class dimensions use the next qualifying size. REQUIRED D₅₀ 5.19 in APRON LENGTH 20 ft FLARED WIDTH 28.33 ft PLACED MASS 39.33 US ton Circular outletLow tailwaterW₂Lₐ · 20 ft 0Required D₅₀2× required

Available stone meets D₅₀

Low tailwater (TW < 0.5Dₒ). Example class dimensions use the next qualifying size.

Stone sizing uses the minimum tailwater of 0.4 effective diameters.

Calculation results

Required D₅₀
5.19 in
Apron length
20 ft
Flared width
28.33 ft
Placed mass
39.33 US ton
Example class D₅₀
6 in
Apron thickness
19.8 in
Upstream apron width
15 ft
Placed volume
715 ft³
Available stone reserve
0.81 in
Tailwater used
2 ft
Effective diameter
5 ft
Actual TW / Dₒ
0.32

Worked calculation

The tailwater floor is 2 ft. Required D₅₀ is about 5.2 in, so the next example class uses 6 in stone, a 20 ft apron and 19.8 in thickness.

D₅₀ = 0.2 D[Q/(√g D⁵ᐟ²)]⁴ᐟ³(D/TW) · W₂ = 3Dₒ + 2Lₐ/3 · mass = placed volume × bulk density.

HEC-14 Eq. 10.4 limits tailwater to 0.4–1.0 effective diameters. USDA classifies site tailwater at 0.5 outlet diameters. For supercritical flow, the effective diameter is the mean of outlet diameter and normal depth. Apron dimensions follow the next qualifying example class in HEC-14 Table 10.1 with a 1:3 flare per side. Larger sizes or tailwater beyond the equation range need site-specific outlet protection analysis.