Worked example · Conveyance

Gutter spread beside a bike lane

The worksheet uses a small allowable spread to keep most of a bike lane clear along a moderate grade.

Inputs

Street section
0–200 cfs
0.02–20 %
0.1–20 %
0.008–0.06
0.5–60 ft
1–24 in
On-grade inlets
0.25–15 ft
0.25–30 ft
0–30 ft/s
0.25–100 ft

Take grate splash-over velocity from HEC-22 Figure 7.8 or grate test data.

Curb and gutter cutaway

Live results
Curb and gutter cutaway Allowable spread exceeded. Grate and curb opening are independent capture alternatives. SPREAD 6.7 ft CURB DEPTH 0.154 ft GRATE CAPTURE 0.74 cfs CURB CAPTURE 0.52 cfs CurbLane limit · 3.7 ftSpread T · 6.7 ft CurbSpread limit2× limit

Allowable spread exceeded

Grate and curb opening are independent capture alternatives.

HEC-22 Equation 7.10 may overstate curb capture for longer openings. Check the FHWA-HRT-22-061 method when the entered or estimated full-capture length reaches 10 ft (3.05 m).

Calculation results

Spread
6.7 ft
Curb depth
0.154 ft
Grate capture
0.74 cfs
Curb capture
0.52 cfs
Approach velocity
2.4 ft/s
Frontal flow Eₒ
51.7 %
Grate efficiency
59.5 %
Curb efficiency
42 %
Grate bypass flow
0.5 cfs
Curb bypass flow
0.72 cfs
Curb length for full capture
21.08 ft
Spread reserve
-3 ft
Curb height reserve
0.346 ft

Worked calculation

Change the pavement cross slope and watch curb depth and spread separately. A narrower spread can arrive with deeper curb flow.

Q = (Kᵤ/n) Sₓ⁵ᐟ³ Sₗ¹ᐟ² T⁸ᐟ³ · d = TSₓ · Eₒ = 1 − (1 − min(W/T, 1))⁸ᐟ³.

Uniform triangular pavement and separate on-grade inlet alternatives. Spread above the curb is outside this model, as are sag flow, depressed gutters, debris, clogging and surcharge. Curb capture uses HEC-22 Equations 7.10 and 7.13. Equation 7.10 can underestimate the required opening length, especially for openings of 10 ft (3.05 m) or more. See FHWA-HRT-22-061 for the alternative method. Results use the published US coefficients and convert to SI.

Open the main calculator

Share this calculation

This link opens the worksheet with your current inputs and units.