Worked example · Conveyance
Gutter spread beside a bike lane
The worksheet uses a small allowable spread to keep most of a bike lane clear along a moderate grade.
Inputs
Curb and gutter cutaway
Live resultsAllowable spread exceeded
Grate and curb opening are independent capture alternatives.
HEC-22 Equation 7.10 may overstate curb capture for longer openings. Check the FHWA-HRT-22-061 method when the entered or estimated full-capture length reaches 10 ft (3.05 m).
Calculation results
- Spread
- 6.7 ft
- Curb depth
- 0.154 ft
- Grate capture
- 0.74 cfs
- Curb capture
- 0.52 cfs
- Approach velocity
- 2.4 ft/s
- Frontal flow Eₒ
- 51.7 %
- Grate efficiency
- 59.5 %
- Curb efficiency
- 42 %
- Grate bypass flow
- 0.5 cfs
- Curb bypass flow
- 0.72 cfs
- Curb length for full capture
- 21.08 ft
- Spread reserve
- -3 ft
- Curb height reserve
- 0.346 ft
Worked calculation
Change the pavement cross slope and watch curb depth and spread separately. A narrower spread can arrive with deeper curb flow.
Q = (Kᵤ/n) Sₓ⁵ᐟ³ Sₗ¹ᐟ² T⁸ᐟ³ · d = TSₓ · Eₒ = 1 − (1 − min(W/T, 1))⁸ᐟ³.
Uniform triangular pavement and separate on-grade inlet alternatives. Spread above the curb is outside this model, as are sag flow, depressed gutters, debris, clogging and surcharge. Curb capture uses HEC-22 Equations 7.10 and 7.13. Equation 7.10 can underestimate the required opening length, especially for openings of 10 ft (3.05 m) or more. See FHWA-HRT-22-061 for the alternative method. Results use the published US coefficients and convert to SI.
More worked examples
Open the main calculatorGutter spread beside a bike lane
Inputs
- Approach flow Q
- 1.24 cfs
- Longitudinal grade
- 1.25 %
- Pavement cross slope
- 2.3 %
- Manning n
- 0.015
- Allowable spread
- 3.7 ft
- Curb height
- 6 in
- Grate width
- 1.6 ft
- Grate length
- 2.2 ft
- Grate splash-over Vₒ
- 5.5 ft/s
- Curb opening length
- 5.5 ft
Results
- Spread
- 6.7 ft
- Curb depth
- 0.154 ft
- Grate capture
- 0.74 cfs
- Curb capture
- 0.52 cfs
- Approach velocity
- 2.4 ft/s
- Frontal flow Eₒ
- 51.7 %
- Grate efficiency
- 59.5 %
- Curb efficiency
- 42 %
- Grate bypass flow
- 0.5 cfs
- Curb bypass flow
- 0.72 cfs
- Curb length for full capture
- 21.08 ft
- Spread reserve
- -3 ft
- Curb height reserve
- 0.346 ft
Allowable spread exceeded
Grate and curb opening are independent capture alternatives.
HEC-22 Equation 7.10 may overstate curb capture for longer openings. Check the FHWA-HRT-22-061 method when the entered or estimated full-capture length reaches 10 ft (3.05 m).
Q = (Kᵤ/n) Sₓ⁵ᐟ³ Sₗ¹ᐟ² T⁸ᐟ³ · d = TSₓ · Eₒ = 1 − (1 − min(W/T, 1))⁸ᐟ³.