Worked example · Concrete quantities

12-Inch Sonotube Piers at 36 Inches Deep

Four right cylinders are 12 in. in diameter and 36 in. tall. The example uses 850 lb of service load per pier on a flat base.

Example inputs

Pour scope
Cylindrical piers
in
in
lb
Material allowances
%
See results

Worked result

Updates as you type
Concrete before waste
0.349 yd³
Concrete to order
0.384 yd³
80 lb bags to order
18

Slab and pier section

Schematic
Slab and pier section 12 in36 in4 cylindrical piersGross bearing 1,532.3 psf

Calculation details

Concrete before waste
0.349 yd³
Concrete to order
0.384 yd³
80 lb bags to order
18
Slab volume
0 yd³
Volume per pier
2.36 ft³
40 lb bags
35
60 lb bags
24
80 lb bags
18
Bearing pressure per pier
1,532 psf

Checks and references

  • Review
    Soil bearing

    The axial load plus concrete self-weight produces 1,532 psf against 1,500 psf entered capacity.

Worked calculation

The steps use US customary units for the reference formulas.

  1. Add the cylindrical piers

    π × (12/24)² ft² × 36/12 ft = 2.36 ft³ per pier. Multiply by 4. Gross base pressure is 1,532 psf per pier.

  2. Order bags or ready mix

    Apply 10% waste to 9.42 ft³. Divide by 0.30, 0.45 or 0.60 ft³ per bag and round up. With 80 lb bags, order 18 bags.

Frequently asked questions

How much concrete fills one 12 in. by 36 in. tube?

The inside volume is π × 0.5² × 3, or about 2.36 ft³ per cylinder before waste.

Why can four 12 in. piers need fewer than four times the rounded bags for one pier?

This estimate rounds after combining all four cylinders, so leftover material can be shared between pours.

Other calculators