Worked example · Concrete quantities
12-Inch Sonotube Piers at 36 Inches Deep
Four right cylinders are 12 in. in diameter and 36 in. tall. The example uses 850 lb of service load per pier on a flat base.
Example inputs
Worked result
Updates as you type- Concrete before waste
- 0.349 yd³
- Concrete to order
- 0.384 yd³
- 80 lb bags to order
- 18
Slab and pier section
SchematicProject inputs
- Concrete to calculate
- Piers only
- Number of piers
- 4
- Pier base diameter
- 12 in
- Concrete depth per pier
- 36 in
- Service load on each pier
- 850 lb
- Allowable soil bearing
- 1,500 psf
- Concrete waste allowance
- 10%
- Bag product weight
- 80 lb bag
Calculation details
- Concrete before waste
- 0.349 yd³
- Concrete to order
- 0.384 yd³
- 80 lb bags to order
- 18
- Slab volume
- 0 yd³
- Volume per pier
- 2.36 ft³
- 40 lb bags
- 35
- 60 lb bags
- 24
- 80 lb bags
- 18
- Bearing pressure per pier
- 1,532 psf
Checks and references
- Review
Soil bearing
The axial load plus concrete self-weight produces 1,532 psf against 1,500 psf entered capacity.
Worked calculation
The steps use US customary units for the reference formulas.
Add the cylindrical piers
π × (12/24)² ft² × 36/12 ft = 2.36 ft³ per pier. Multiply by 4. Gross base pressure is 1,532 psf per pier.
Order bags or ready mix
Apply 10% waste to 9.42 ft³. Divide by 0.30, 0.45 or 0.60 ft³ per bag and round up. With 80 lb bags, order 18 bags.
Enter valid values to see the steps for this layout.
Frequently asked questions
How much concrete fills one 12 in. by 36 in. tube?
The inside volume is π × 0.5² × 3, or about 2.36 ft³ per cylinder before waste.
Why can four 12 in. piers need fewer than four times the rounded bags for one pier?
This estimate rounds after combining all four cylinders, so leftover material can be shared between pours.