Heat Pump COP vs. Gas, Propane & Oil Cost Calculator

Compare heating costs per unit of useful heat and find the economic COP crossover at 47°F, 17°F and 5°F. Estimate annual bills and CO₂ for the same delivered heat.

Utility rates and efficiency
$/kWh
$/therm
$/US gal
$/US gal
%
%
%
Heat pump performance
Annual comparison
MMBtu
%

The three shares represent delivered heat and must add up to 100%.

%
%
kg CO₂/kWh

Example assumption. Enter your local electricity emissions factor.

Heat pump bill savings / year
10.65 USD
Break-even COP vs. natural gas
2.98
CO₂ reduction / year
1,139 kg CO₂

Positive savings show that the modeled heat pump costs less than the baseline fuel.

Heating cost crossover

Delivered heating cost by outdoor temperatureThe three heat pump costs are 24.68 $/MMBtu, 18.04 $/MMBtu, 12.34 $/MMBtu at the cold-to-warm anchors. Baseline: 26.4 °F. $/MMBtu0102030405 °F17 °F47 °FNatural gasPropaneHeating oilHeat pump
The heat pump curve uses linearly interpolated COP between the three anchors. Horizontal lines show each fossil fuel’s cost after AFUE.
Load-weighted seasonal COP
3.01
Heat pump electricity (kWh/year)
5,351
Heat pump bill / year
856.19 USD
Heat pump CO₂ / year
2,033 kg CO₂
Heat pump cost at 5 °F
24.68 $/MMBtu
Heat pump cost at 17 °F
18.04 $/MMBtu
Heat pump cost at 47 °F
12.34 $/MMBtu

Fossil fuel comparison

Natural gas Baseline

Delivered heat price
15.76 $/MMBtu
Break-even COP
2.98
Crossover temperature
26.4 °F
Bill / year
866.85 USD
CO₂ / year
3,172 kg CO₂

Propane

Delivered heat price
32.8 $/MMBtu
Break-even COP
1.43
Crossover temperature
Outside chart range
Bill / year
1,804.23 USD
CO₂ / year
3,842 kg CO₂

Heating oil

Delivered heat price
30.58 $/MMBtu
Break-even COP
1.53
Crossover temperature
Outside chart range
Bill / year
1,681.89 USD
CO₂ / year
4,786 kg CO₂
Download

How this calculation works

Heat pump cost per delivered MMBtu equals 293.071 × electricity price ÷ COP. Fuel cost per delivered MMBtu is the retail price divided by fuel heat content and AFUE. The crossover COP is the electricity-price numerator divided by the fuel’s delivered heat price.

The seasonal COP is the delivered-heat-weighted harmonic mean of the three entered COPs. Bin percentages describe heat output, so a colder bin can represent a larger share of heating than of hours.

Fuel heat content uses 0.100 MMBtu per therm, 0.091452 MMBtu per US gallon of propane and 0.1385 MMBtu per US gallon of heating oil. Direct combustion emits 53.06, 62.87 and 73.96 kg CO₂ per MMBtu of fuel input, respectively. Heat pump emissions use the entered electricity factor.

The crossover is economic. Check temperature-specific capacity, defrost, backup heat, utility fixed charges, equipment and distribution losses separately.

References

Frequently asked questions

What is the difference between a COP crossover and a heat pump capacity balance point?

At the COP crossover, the two sources cost the same to deliver heat. At the capacity balance point, the heat pump can just meet the building’s heat load. Capacity also depends on the equipment and the building.

Why does the annual calculation use a harmonic mean of COP?

Each heat bin uses electricity equal to delivered heat divided by COP. Weighting the inverse COP by delivered heat preserves the total electricity when the bins are combined.