Worked example
Cold-Climate Heat Pump on a Low-Carbon Grid
A 100 MMBtu home has a large cold-weather heating share. It uses a 92% gas comparison and an illustrative low-carbon electricity intensity of 0.08 kg CO₂/kWh.
Try it Raise grid intensity to 0.55 kg/kWh while keeping fuel and electric rates fixed. Check which results respond to emissions and which depend on cost.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Heat pump bill savings / year
- USD
- Break-even COP vs. natural gas
- CO₂ reduction / year
- kg CO₂
The modeled heat pump costs more per year than the selected baseline fuel.
Heating cost crossover
- Load-weighted seasonal COP
- Heat pump electricity (kWh/year)
- Heat pump bill / year
- USD
- Heat pump CO₂ / year
- kg CO₂
- Heat pump cost at 5 °F
- $/MMBtu
- Heat pump cost at 17 °F
- $/MMBtu
- Heat pump cost at 47 °F
- $/MMBtu
Fossil fuel comparison
Natural gas Baseline
- Delivered heat price
- 15.76 $/MMBtu
- Break-even COP
- 2.98
- Crossover temperature
- 21.4 °F
- Bill / year
- 1,576.09 USD
- CO₂ / year
- 5,767 kg CO₂
Propane
- Delivered heat price
- 32.8 $/MMBtu
- Break-even COP
- 1.43
- Crossover temperature
- Outside chart range
- Bill / year
- 3,280.41 USD
- CO₂ / year
- 6,986 kg CO₂
Heating oil
- Delivered heat price
- 30.58 $/MMBtu
- Break-even COP
- 1.53
- Crossover temperature
- Outside chart range
- Bill / year
- 3,057.97 USD
- CO₂ / year
- 8,701 kg CO₂
Inputs used
- Electricity rate
- 0.16 $/kWh
- Natural gas rate
- 1.45 $/therm
- Propane rate
- 2.7 $/US gal
- Heating oil rate
- 3.6 $/US gal
- Gas appliance AFUE
- 92 %
- Propane appliance AFUE
- 90 %
- Oil appliance AFUE
- 85 %
- COP at 47°F
- 4
- COP at 17°F
- 2.8
- COP at 5°F
- 2.1
- Baseline fuel
- Natural gas
- Annual delivered heat
- 100 MMBtu
- Share of heat at 47°F
- 25 %
- Share of heat at 17°F
- 45 %
- Share of heat at 5°F
- 30 %
- Electric grid CO₂ intensity
- 0.08 kg CO₂/kWh
How this calculation works
Heat pump cost per delivered MMBtu equals 293.071 × electricity price ÷ COP. Fuel cost per delivered MMBtu is the retail price divided by fuel heat content and AFUE. The crossover COP is the electricity-price numerator divided by the fuel’s delivered heat price.
The seasonal COP is the delivered-heat-weighted harmonic mean of the three entered COPs. Bin percentages describe heat output, so a colder bin can represent a larger share of heating than of hours.
Fuel heat content uses 0.100 MMBtu per therm, 0.091452 MMBtu per US gallon of propane and 0.1385 MMBtu per US gallon of heating oil. Direct combustion emits 53.06, 62.87 and 73.96 kg CO₂ per MMBtu of fuel input, respectively. Heat pump emissions use the entered electricity factor.
The crossover is economic. Check temperature-specific capacity, defrost, backup heat, utility fixed charges, equipment and distribution losses separately.
References
Frequently asked questions
Why can heat pump CO₂ go down while the heating bill goes up?
The operating cost uses retail prices while the emissions calculation uses grid and combustion emission factors. A clean grid can be expensive per kilowatt-hour.
Which electricity emissions factor should I use for this cold-climate run?
Use a local factor suited to your purpose. An annual average describes typical electricity consumption, while a marginal or time-specific factor describes a different scenario.