Worked example
Propane Cabin vs. a Heat Pump at $0.21/kWh
A cabin uses just 32 MMBtu of delivered heat over the year and buys propane at $2.75 per gallon. The comparison assumes a 90% propane appliance and a heavy shoulder-season share.
Try it Move some delivered heat from the mildest bin to the coldest bin. Keep the total at 100% and check how annual electricity grows.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Heat pump bill savings / year
- USD
- Break-even COP vs. propane
- CO₂ reduction / year
- kg CO₂
Positive savings show that the modeled heat pump costs less than the baseline fuel.
Heating cost crossover
- Load-weighted seasonal COP
- Heat pump electricity (kWh/year)
- Heat pump bill / year
- USD
- Heat pump CO₂ / year
- kg CO₂
- Heat pump cost at 5 °F
- $/MMBtu
- Heat pump cost at 17 °F
- $/MMBtu
- Heat pump cost at 47 °F
- $/MMBtu
Fossil fuel comparison
Natural gas
- Delivered heat price
- 15.76 $/MMBtu
- Break-even COP
- 3.9
- Crossover temperature
- Outside chart range
- Bill / year
- 504.35 USD
- CO₂ / year
- 1,846 kg CO₂
Propane Baseline
- Delivered heat price
- 33.41 $/MMBtu
- Break-even COP
- 1.84
- Crossover temperature
- 6.7 °F
- Bill / year
- 1,069.17 USD
- CO₂ / year
- 2,235 kg CO₂
Heating oil
- Delivered heat price
- 30.58 $/MMBtu
- Break-even COP
- 2.01
- Crossover temperature
- 9.8 °F
- Bill / year
- 978.55 USD
- CO₂ / year
- 2,784 kg CO₂
Inputs used
- Electricity rate
- 0.21 $/kWh
- Natural gas rate
- 1.45 $/therm
- Propane rate
- 2.75 $/US gal
- Heating oil rate
- 3.6 $/US gal
- Gas appliance AFUE
- 92 %
- Propane appliance AFUE
- 90 %
- Oil appliance AFUE
- 85 %
- COP at 47°F
- 3.7
- COP at 17°F
- 2.4
- COP at 5°F
- 1.75
- Baseline fuel
- Propane
- Annual delivered heat
- 32 MMBtu
- Share of heat at 47°F
- 70 %
- Share of heat at 17°F
- 25 %
- Share of heat at 5°F
- 5 %
- Electric grid CO₂ intensity
- 0.38 kg CO₂/kWh
How this calculation works
Heat pump cost per delivered MMBtu equals 293.071 × electricity price ÷ COP. Fuel cost per delivered MMBtu is the retail price divided by fuel heat content and AFUE. The crossover COP is the electricity-price numerator divided by the fuel’s delivered heat price.
The seasonal COP is the delivered-heat-weighted harmonic mean of the three entered COPs. Bin percentages describe heat output, so a colder bin can represent a larger share of heating than of hours.
Fuel heat content uses 0.100 MMBtu per therm, 0.091452 MMBtu per US gallon of propane and 0.1385 MMBtu per US gallon of heating oil. Direct combustion emits 53.06, 62.87 and 73.96 kg CO₂ per MMBtu of fuel input, respectively. Heat pump emissions use the entered electricity factor.
The crossover is economic. Check temperature-specific capacity, defrost, backup heat, utility fixed charges, equipment and distribution losses separately.
References
Frequently asked questions
Why use delivered heat rather than tank gallons for the cabin annual input?
The comparison holds useful heat steady. To estimate it from tank deliveries, multiply gallons by fuel heat content and seasonal efficiency after accounting for other propane uses.
Can a cabin thermostat setback change the seasonal COP estimate?
It can move some of the load to different conditions. Edit the delivered-heat shares and COP values when you have data that captures the changed operation.