Propane Cabin vs. a Heat Pump at $0.21/kWh

A cabin uses just 32 MMBtu of delivered heat over the year and buys propane at $2.75 per gallon. The comparison assumes a 90% propane appliance and a heavy shoulder-season share.

Try it Move some delivered heat from the mildest bin to the coldest bin. Keep the total at 100% and check how annual electricity grows.

Utility rates and efficiency
$/kWh
$/therm
$/US gal
$/US gal
%
%
%
Heat pump performance
Annual comparison
MMBtu
%

The three shares represent delivered heat and must add up to 100%.

%
%
kg CO₂/kWh

Example assumption. Enter your local electricity emissions factor.

Heat pump bill savings / year
435.15 USD
Break-even COP vs. propane
1.84
CO₂ reduction / year
1,088 kg CO₂

Positive savings show that the modeled heat pump costs less than the baseline fuel.

Heating cost crossover

Delivered heating cost by outdoor temperatureThe three heat pump costs are 35.17 $/MMBtu, 25.64 $/MMBtu, 16.63 $/MMBtu at the cold-to-warm anchors. Baseline: 6.7 °F. $/MMBtu0102030405 °F17 °F47 °FNatural gasPropaneHeating oilHeat pump
The heat pump curve uses linearly interpolated COP between the three anchors. Horizontal lines show each fossil fuel’s cost after AFUE.
Load-weighted seasonal COP
3.11
Heat pump electricity (kWh/year)
3,019
Heat pump bill / year
634.02 USD
Heat pump CO₂ / year
1,147 kg CO₂
Heat pump cost at 5 °F
35.17 $/MMBtu
Heat pump cost at 17 °F
25.64 $/MMBtu
Heat pump cost at 47 °F
16.63 $/MMBtu

Fossil fuel comparison

Natural gas

Delivered heat price
15.76 $/MMBtu
Break-even COP
3.9
Crossover temperature
Outside chart range
Bill / year
504.35 USD
CO₂ / year
1,846 kg CO₂

Propane Baseline

Delivered heat price
33.41 $/MMBtu
Break-even COP
1.84
Crossover temperature
6.7 °F
Bill / year
1,069.17 USD
CO₂ / year
2,235 kg CO₂

Heating oil

Delivered heat price
30.58 $/MMBtu
Break-even COP
2.01
Crossover temperature
9.8 °F
Bill / year
978.55 USD
CO₂ / year
2,784 kg CO₂
Download

How this calculation works

Heat pump cost per delivered MMBtu equals 293.071 × electricity price ÷ COP. Fuel cost per delivered MMBtu is the retail price divided by fuel heat content and AFUE. The crossover COP is the electricity-price numerator divided by the fuel’s delivered heat price.

The seasonal COP is the delivered-heat-weighted harmonic mean of the three entered COPs. Bin percentages describe heat output, so a colder bin can represent a larger share of heating than of hours.

Fuel heat content uses 0.100 MMBtu per therm, 0.091452 MMBtu per US gallon of propane and 0.1385 MMBtu per US gallon of heating oil. Direct combustion emits 53.06, 62.87 and 73.96 kg CO₂ per MMBtu of fuel input, respectively. Heat pump emissions use the entered electricity factor.

The crossover is economic. Check temperature-specific capacity, defrost, backup heat, utility fixed charges, equipment and distribution losses separately.

References

Frequently asked questions

Why use delivered heat rather than tank gallons for the cabin annual input?

The comparison holds useful heat steady. To estimate it from tank deliveries, multiply gallons by fuel heat content and seasonal efficiency after accounting for other propane uses.

Can a cabin thermostat setback change the seasonal COP estimate?

It can move some of the load to different conditions. Edit the delivered-heat shares and COP values when you have data that captures the changed operation.